1 : mark 1 \documentclass{book}
2 :    
3 :     \author{Oslo University College, Norway}
4 :     \title{\sc High Volume Services Laboratory Handbook\\Version 0.1}
5 :     \date{\today}
6 :    
7 :     \usepackage{times} % -- good
8 :     \usepackage{fancyheadings}
9 :     \usepackage{tocloft}
10 :    
11 :     %\usepackage{amsthm}
12 :     \usepackage{a4}
13 :     \usepackage{shadethm}
14 :     \pagestyle{fancyplain}
15 :     \lhead[\fancyplain{}{}]{\fancyplain{}{\rightmark}}
16 :     \rhead[\fancyplain{}{\leftmark}]{\fancyplain{}{}}
17 :    
18 :    
19 :     %\textheight 20cm
20 :     \textwidth 15.5cm
21 :     \oddsidemargin -20pt
22 :     \evensidemargin -20pt
23 :    
24 :    
25 :     %\topmargin -30pt
26 :     \usepackage{url}
27 :     \usepackage{tabularx}
28 :     \usepackage{fancybox}
29 :     \usepackage{fancyvrb}
30 :     \usepackage{epsfig}
31 :     %\usepackage{alltt}
32 :    
33 :    
34 :    
35 :     \urlstyle{rm}
36 :     %\def\UrlFont{\em}
37 :    
38 :    
39 :     \newenvironment{code}%
40 :     {\begin{Sbox}\begin{minipage}{.9\textwidth}\scriptsize}%
41 :     {\end{minipage}\end{Sbox}%
42 :     \begin{center}\setlength{\fboxsep}{2pt}\setlength{\fboxrule}{1pt}%
43 :     \fbox{\TheSbox}\end{center}}
44 :    
45 :    
46 :     \def\sex{\begin{alltt}\small}
47 :     \def\esex{\end{alltt}}
48 :     \def\ex{\begin{alltt}}
49 :     \def\eex{\end{alltt}}
50 :    
51 :     \def\file{\tt\small}
52 :    
53 :     \def\samp{\tt\small}
54 :     \def\kbd{\tt\small}
55 :     \def\key{\sc}
56 :     \def\var{\em}
57 :     \def\beq{\begin{eqnarray}}
58 :     \def\eeq{\end{eqnarray}}
59 :     \def\2{\frac{1}{2}}
60 :    
61 :     %\setcounter{tocdepth}{1}
62 :    
63 :    
64 :    
65 :     \newshadetheorem{todo}{TO DO!}
66 :     %\newshadetheorem{defin}{Definition}
67 :     %\newtheorem*{corollary}{Corollary to principle}
68 :     %\newshadetheorem{suggestion}{Suggestion}
69 :     \newtheorem{example}{Example}
70 :     \newtheorem{question}{Question}
71 :     \makeindex
72 :    
73 :    
74 :     \begin{document}
75 :     %\begin{figure}[ht]
76 :     %\psfig{file=NetlabCover.eps,width=14cm}
77 :     %\end{figure}
78 :     \maketitle
79 :     \bibliographystyle{plain}
80 :    
81 :     %\setlength{\cftchapnumwidth}{18pt}
82 :     %\setlength{\cftsecnumwidth}{31pt}
83 :     %\setlength{\cftsubsecnumwidth}{40pt}
84 :    
85 :     \tableofcontents
86 :    
87 :    
88 :    
89 :     %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
90 :    
91 :     \chapter{Introduction}
92 :    
93 :     This is a working document. It will eventually be a handbook for a laboratory
94 :     course in server room design.
95 :    
96 :     Contributors to this booklet: Mark Burgess, Claudia Eriksen, Tore
97 :     M. Jonassen Sven Ingebrigt Ulland, Gard Undheim.
98 :    
99 :     %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
100 :    
101 :     \part{Data Centre Science}
102 :    
103 :     \chapter{Safety and responsibility in the Lab}
104 :    
105 :    
106 :     Oslo University College is committed to providing a safe and healthy
107 :     working environment for its students and staff. You are expected to
108 :     learn working practices that you will take with you when you leave
109 :     the College. It is your ethical duty to spread safe working practices
110 :     and procedures beyond this College in the workplace.
111 :    
112 :    
113 :     Oslo University College requires its students, staff, and faculty to
114 :     adhere to basic General Laboratory Safety Rules in the Electrical
115 :     Engineering laboratories.
116 :    
117 :     These rules apply to everyone. If you see someone ignoring the rules,
118 :     it is your duty to remind them of their responsibilities.
119 :    
120 :     \noindent {\em This discipline is a mark of professionalism -- it is not for
121 :     annoyance or for show. You might find other labs that do not care about
122 :     safety, but as a student of Oslo University College, we expect the highest
123 :     standards.}
124 :    
125 :     \section{General Laboratory Safety Rules}
126 :    
127 :     \begin{enumerate}
128 :     \item The lab is a dry and noisy environment. You should try to organize
129 :     your work so that you do not spend more than three or four hours in the lab
130 :     at any one time. If you need to talk to your work partners, go out of the
131 :     lab into a quiet area rather than shouting.
132 :    
133 :     \item Food and drink must not be brought into, stored in
134 :     or consumed in a laboratory.
135 :    
136 :     \item Never wear personal headphones or play music to drown out the noise:
137 :     you can damage your hearing by playing loud music, and cause accidents by
138 :     being distracted. Your full attention should be on your work.
139 :    
140 :     \item Shoes must be worn, and appropriate
141 :     personal clothing shall be worn in laboratories.
142 :    
143 :     \item Do not wear items of metal jewelry when using electronic equipment. You might cause a short-circuit, get a shock or get the jewelry caught in something.
144 :    
145 :     \item Bags and coats should be left at the doorway.
146 :    
147 :     \item {\em BE TIDY AND TREAT ALL EQUIPMENT WITH RESPECT}. Do not tread on or run over cables with
148 :     chairs or heavy objects.
149 :    
150 :     \item Never drop items on the floor. Always put equipment in the correct box or storage place provided for it. Fold cables neatly to avoid long-term damage to them.
151 :    
152 :     \item Learn and know what to do in an emergency.
153 :    
154 :     \item Do not expose yourself or others to risk. Do not joke around in the lab.
155 :    
156 :     \item Un-authorized persons MUST NOT be admitted to the laboratory.
157 :    
158 :     'Authorized' means having business in the laboratory with the permission
159 :     of the College. No-one under the age of eighteen
160 :     may enter the lab unsupervised. Only trained individuals and students enrolled in courses using the lab may touch the equipment.
161 :    
162 :     \item Laboratory shall remain locked when unoccupied.
163 :     \item Never open (remove cover) of any equipment in the laboratories, unless you are
164 :     instructed to do so.
165 :     \item Report all problems to drift@iu.hio.no (extensions 3268/3264/3263)
166 :     \end{enumerate}
167 :    
168 :     \section{Electrical Safety Guidelines}
169 :    
170 :     \begin{enumerate}
171 :     \item Be familiar with the electrical hazards associated with your workplace.
172 :    
173 :     \item Be as careful for the safety of others as for yourself. Think before
174 :     you act. Be tidy and systematic.
175 :     \item Avoid bulky, loose or trailing clothes. Avoid long loose hair. Remove
176 :     metal bracelets or watch-straps.
177 :    
178 :     \item Do not take food or drink into the laboratory. Avoid wet
179 :     hands and clothing. \item Use extension cords (skj\o
180 :     teledninger) only when necessary and only on a temporary basis.
181 :     Request new power outlets if your work requires equipment in an
182 :     area without an outlet.
183 :    
184 :     \item ALWAYS report damaged cords and cables, including cables that become hot, or with
185 :     exposed wiring. Never ignore these or replace them for others to use.
186 :    
187 :    
188 :     \item Experiments left unattended should be isolated. If
189 :     for a special reason, it must be left on, a barrier and a warning notice
190 :     are required.
191 :     \item Equipment found to be faulty in any way should be reported immediately
192 :     and not used until it is inspected and declared safe.
193 :    
194 :     \item Voltages above 50 V RMS AC and 120 V DC are always dangerous. Extra precautions
195 :     should be considered as voltage levels are increased.
196 :    
197 :     \item Never make any changes to circuits or mechanical layout without first
198 :     isolating the circuit by switching off and removing connections to supplies.
199 :    
200 :     \item Know what you must do in an emergency.
201 :    
202 :     \item Be acquainted with the Emergency Power Off:
203 :    
204 :    
205 :     \item When touching equipment that might be electrically "live" always use the {\em back of your hand}. Never grip anything with your fingers, since and electric shock will tend to make you grip tighter.
206 :    
207 :     \item Electrical power sockets should not be overloaded.
208 :    
209 :     \item {\b No cables should ever be stretched.} Tape them firmly to a table or floor. Remember that people can trip over cables.
210 :    
211 :     \item Hold the plug firmly by the insulating cover when plugging it in or unplugging it.
212 :     {\bf NEVER} unplug an electrical device by pulling on its cord!
213 :    
214 :     \item Do not attempt to lift or move heavy equipment alone.
215 :    
216 :     \end{enumerate}
217 :    
218 :     \section{Electrical Emergency Response}
219 :    
220 :     The following instructions provide guidelines for handling two types
221 :     of electrical emergencies:
222 :    
223 :    
224 :     When someone suffers serious electrical shock, he or she may be
225 :     knocked unconscious. If the victim is still in contact with the
226 :     electrical current, immediately turn off the electrical power
227 :     source. If you cannot disconnect the power source, push in the
228 :     Emergency Power Off button.
229 :     \begin{enumerate}
230 :    
231 :     \item Do not touch a victim that is still in contact with a power source; you
232 :     could electrocute yourself.
233 :    
234 :     \item Have someone call for emergency medical assistance immediately. Administer
235 :     first-aid, as appropriate.
236 :    
237 :     \item If an electrical fire occurs, try to disconnect the electrical power
238 :     source, if possible.
239 :    
240 :    
241 :    
242 :     \item In case of fire, pull out power sockets if possible, taking care not to be electrocuted.
243 :     \item Use of {\bf clean water} to put out electrical fire is acceptable.
244 :     \end{enumerate}
245 :    
246 :    
247 :     \section{Handling equipment}
248 :    
249 :    
250 :     All electronic equipment should be treated as highly fragile and
251 :     easily damaged, regardless of how sturdy it is. Today we are far too
252 :     blas\'e towards electronic equipment.
253 :     \begin{itemize}
254 :     \item Never insert or remove power cords to equipment without ensuring that it is switched off.
255 :     \item Take care when inserting multi-pin connectors that the pins are oriented the right way up and that no pins are bent on insertion.
256 :     \end{itemize}
257 :     Moreover:
258 :     \begin{itemize}
259 :     \item {\em Read instructions:}
260 :     When dealing with hardware, one should always look for and {\em read}
261 :     instructions in a manual. It is foolish to make assumptions about expensive
262 :     purchases. Instructions are there for a reason.
263 :     \item {\em Interfaces and connectors:}
264 :     Hardware is often connected to an interface by a cable or connector.
265 :     Obtaining the correct cable is of vital importance. Many manufacturers
266 :     use cables which look similar, superficially, but which actually are
267 :     different. An incorrect cable can result in damage to an interface.
268 :     Modem cables in particular can damage a computer or modem if they
269 :     are incorrectly wired, since some computers supply power through these
270 :     cables which can damage equipment which does not expect to find a
271 :     power supply coming across the cable.
272 :    
273 :     \item {\em Handling components:}
274 :     Modern day CMOS chips work at low voltages (typically 5 volts or lower).
275 :     Standing on the floor with insulating shoes, you can pick up a
276 :     static electric charge of several thousand volts. Such a charge
277 :     can instantly destroy computer chips. Before touching any
278 :     computer components, earth yourself by touching the metal
279 :     casing of the computer. If you are installing equipment inside
280 :     a computer, wear a conductive wrist strap. Avoid wearing rubber sandals
281 :     or shoes that insulate you from Earth when dealing with
282 :     open case equipment, since these cause the body to
283 :     build up charge that can discharge through that equipment; on the
284 :     other hand this might be good advice when working around high voltage
285 :     or current sources.
286 :     \index{Components, handling}
287 :     \index{Handling components}
288 :    
289 :     \item {\em Disks:}
290 :     Disk technology has been improving steadily for two decades. The most
291 :     common disk types, in the workplace, fall into two families: ATA
292 :     (formerly IDE) and SCSI. The original IDE (Integrated Drive
293 :     Electronics) and SCSI (Small Computer Software Interface) had
294 :     properties that have since evolved faster than the prejudices about
295 :     them. ATA (formerly IDE) disks are now generally cheaper than SCSI
296 :     disks (due to volume sales) and excel at sequential access, but SCSI
297 :     disks have traditionally been more efficient at handling multiple
298 :     accesses due to a multitasking bus design, and are therefore better in
299 :     multitasking systems, where random access is important. However,
300 :     filesystem design also plays an important role in determining the
301 :     perceived performance of each; i.e. how operating systems utilize
302 :     buses during updates is at least as important as bus performance
303 :     itself. Interesting comparisons show that IDE technology has caught up
304 :     with the head start that SCSI disks once had\cite{white1} for many
305 :     purposes, but not all.
306 :    
307 :     SCSI\cite{lisa93157} comes in several varieties, SCSI 1, SCSI
308 :     2, wide SCSI, fast-wide etc. The difference has to do with the width
309 :     of the data-bus and the number of disks which can be attached to each
310 :     controller. There are presently three SCSI standards SCSI-1, SCSI-2
311 :     and SCSI-3. The SCSI-2 standard defines also wide, fast and fast/wide
312 :     SCSI.
313 :     Each SCSI disk has its own address (or number) which must be set by
314 :     changing a setting on the disk-cabinet or by changing jumper settings
315 :     inside the cabinet. Newer disks have programmable identities.
316 :     \index{SCSI disks}
317 :     \index{IDE disks}
318 :     \index{ATA disks}
319 :     Disk chain buses must be terminated with a proper terminating
320 :     connector. Newer disks often contain automatic termination mechanisms
321 :     integrated into the hardware.
322 :     The devices on the SCSI bus talk to the computer through a
323 :     controller. On modern PCs the SCSI controller is usually connected to
324 :     the PCI bus either as an on-board solution on motherboards or as a
325 :     separate card in a PCI slot. Other buses are also used as the carrier
326 :     of the SCSI protocol, like FireWire (IEEE 1394) and USB. The SCSI
327 :     standard also supports removable media devices (CD-ROM, CD-R, Zip
328 :     drives), video frame grabbers, scanners and tape streamers (DAT, DLT).
329 :    
330 :    
331 :     \item {\em Memory:}
332 :     Memory chips are sold on small pluggable boards. They
333 :     are sold in different sizes and with different speeds.
334 :     A computer has a number of slots where they can be installed.
335 :     When buying and installing RAM, remember
336 :     \index{SIMM}
337 :     \begin{itemize}
338 :    
339 :     \item The physical size of memory plug-ins is important. Not all of
340 :     them fit into all sockets.
341 :    
342 :     \item Memory is sold in units with different capacities and data rates. One
343 :     must find out what size can be used in a system. In many cases one
344 :     may not mix different types.
345 :    
346 :     \item There are various incompatible kinds of RAM that work in
347 :     different ways. Error correcting RAM, for instance, is tolerant to
348 :     error from external noise sources like cosmic rays and other ultra
349 :     short wave disturbances. It is recommended for important servers,
350 :     where stability is paramount.
351 :    
352 :     \item On some computers one must fill up RAM slots in a particular
353 :     order, otherwise the system will not be able to find them.
354 :     \end{itemize}
355 :    
356 :     \end{itemize}
357 :    
358 :    
359 :     \index{Weather}
360 :     Another aspect of hardware is the extent to which weather and
361 :     environment are important for operation..
362 :    
363 :     \begin{itemize}
364 :    
365 :     \item {\em Lightning:}
366 :     strikes can destroy fragile equipment. No fuse will protect hardware
367 :     from a lightning strike. Transistors and CMOS chips burn out much faster
368 :     than any fuse. Electronic spike protectors can help here, but nothing
369 :     will protect against a direct strike.
370 :    
371 :     \item {\em Power:}
372 :     failure can cause disk damage and loss of data. A UPS
373 :     (Un-interruptible power supply) can help.
374 :    
375 :     \item {\em Heat:}
376 :     The blazing summer heat or a poorly placed heater oven can cause
377 :     systems to overheat and suddenly black out. One should not let the
378 :     ambient temperature near a computer to rise much above about 25
379 :     degrees Centigrade. Clearly some equipment can tolerate heat, better
380 :     than other equipment. Bear in mind that metals expand significantly,
381 :     so moving parts like disks will be worst affected by heat. Increased
382 :     temperature also increases noise levels that can reduce network
383 :     capacities by a fraction of a percent. While this might not sound like
384 :     much, a fraction of a percent of a Giga-bit cable is a lot of
385 :     capacity. Heat can cause RAM to operate unpredictably and disks to
386 :     misread/miswrite. Good ventilation is essential for computers and
387 :     screens for avoiding electrical faults.
388 :    
389 :     \item {\em Cold:}
390 :     Sudden changes from hot to cold are just as bad. They can
391 :     cause unpredictable changes in electrical properties of chips and
392 :     cause systems to crash. In the long term, these changes could lead
393 :     to cracks in the circuit boards and irreparable chip damage.
394 :    
395 :     \item {\em Humidity:} In times of very cold weather and very
396 :     dry heat, the humidity falls to very low levels. At these times, the
397 :     amount of static electricity builds up to quite high levels, without
398 :     dissipating. This can be a risk to electronic circuitry. Humans pick
399 :     up charge just by walking around, that can destroy fragile
400 :     circuitry. Paper sticks together causing paper crashes in laser
401 :     printers. Too much humidity can lead to condensation and short circuits.
402 :    
403 :     \end{itemize}
404 :     How could you go about verifying that conditions in the lab are
405 :     appropriate?
406 :    
407 :    
408 :     %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
409 :    
410 :    
411 :    
412 :     \chapter{Power in the lab}
413 :    
414 :     Power consumption is defined as the flow of energy, per unit time, in
415 :     or out of a system. It is measured in Joules per second, or Watts or
416 :     Volt-Amperes, which are all equivalent.
417 :    
418 :     Electrical power is needed to make computers run. It is also needed
419 :     for lighting and cooling. Every electrical device generates heat, including
420 :     cooling equipment! Once you have estimated your power needs for computers,
421 :     you should add about 70\% again for the cost of cooling.
422 :    
423 :    
424 :     You should acquaint yourself with the power system in our local country.
425 :     Look at the excellent information on Wikepedia about international mains supplies.
426 :     \begin{itemize}
427 :     \item http://en.wikipedia.org/wiki/Mains\_electricity
428 :    
429 :     \item http://en.wikipedia.org/wiki/Domestic\_AC\_power\_plugs\_and\_sockets
430 :    
431 :     \item http://en.wikipedia.org/wiki/List\_of\_countries\_with\_mains\_power\_plugs,\_voltages\_and\_frequencies
432 :     \end{itemize}
433 :    
434 :     The following text is from Wikepedia:
435 :     \bigskip
436 :    
437 :     \framebox{
438 :     \begin{minipage}[t]{0.8\linewidth}
439 :    
440 :     {\em European and most other countries use a supply that is within 10\% of
441 :     230 V, whereas Japan and most of the Americas use between 100 and 127
442 :     V. Following voltage harmonisation co-ordinated with CENELEC
443 :     countries, all electricity supply within the EU is now nominally 230 V
444 :     +/− 10\% (though some countries have stricter specifications: for
445 :     example, the UK specifies 230 V +10\% -6\%). In practice this means that
446 :     countries such as the UK that previously supplied 240 V continue to do
447 :     so, and those that previously supplied 220 V continue to do
448 :     so. However equipment should be designed to accept any voltages within
449 :     the specified range, and in practice most do so.
450 :     Similarly, Australia
451 :     has converted to 230 V as the nominal standard, and like the UK, 240 V
452 :     is within the allowable tolerance. "240 volt" spoken as "two forty
453 :     volt" remains a synonym for mains in Australian and British English.
454 :    
455 :    
456 :     In the United States and Canada, mains power is referred to by a
457 :     variety of names, including household power (or household
458 :     electricity), domestic power, wall power (because it comes from a
459 :     power outlet in the wall), or simply "AC power." A close synonym for
460 :     "mains" in Canadian provinces that use hydroelectric power is "hydro".
461 :     ANSI standard C84.1 and Canadian standard CAN3-C235 specify that the
462 :     nominal voltage at the output should be 120 V and allow a range of 114
463 :     to 126 V.
464 :    
465 :     In Japan, the electrical power supply to households is at
466 :     100 V. Eastern and northern parts of Honshu (including Tokyo) and
467 :     Hokkaido have a frequency of 50 Hz, whereas western Honshu (including
468 :     Nagoya, Osaka, and Hiroshima), Shikoku, Kyushu and Okinawa operate at
469 :     60 Hz. To accommodate the difference, appliances marketed in Japan can
470 :     often be switched between the two frequencies.}
471 :    
472 :     \end{minipage}
473 :     }
474 :    
475 :    
476 :     \section{Power Interference: wireless signals and computer power supplies}
477 :    
478 :     \begin{itemize}
479 :     \item How much electrical power does a computer use?
480 :    
481 :     \item Does it use the same amount of power in your house as it does in a data centre?
482 :     \end{itemize}
483 :    
484 :     To answer these questions, we need to know some basic physics of waves
485 :     - because A.C. power is a wave, and energy is carried in the wave-like
486 :     motion of the electrons of the wires. Recall your basic networking:
487 :     the same principles of energy transfer apply to the alternating currents feeding
488 :     computer power supplies as to the absorption of wireless signals in
489 :     walls. We need to understand how much of a wave is absorbed and does
490 :     work (heating up the wall or driving and heating up the CPU) and how
491 :     much simply passes through or is refleected back again.
492 :    
493 :     Electronic circuitry has two kinds of components:
494 :     \begin{itemize}
495 :    
496 :     \item {\em Resistive components} absorb and dissipate power as heat. They obey Ohm's law.
497 :    
498 :     \item {\em Reactive components} absorb and return energy (like a battery), by storing
499 :     it in electromagnetic fields. They include capacitors (condensers)
500 :     and inductors (electro-magnetic coils).
501 :     \end{itemize}
502 :    
503 :     Reactive components (inductors and capacitors) store and return most
504 :     of the power they use. This means that if we wait for a full cycle of the
505 :     alternating wave, we will get back most of what we put in again. Resistive
506 :     components, on the other hand, convert most of the energy going into them into
507 :     heat.
508 :    
509 :     What this means is that, if we measure the absorption of energy (the
510 :     power consumption) of a device we must follow its progress over many
511 :     cycles and take an average to see how much is being absorbed forever,
512 :     and how much is being borrowed as a short-term loan and returned. In
513 :     other words, we are interested in the {\em trend}, not the
514 :     fluctuations of energy transfer.
515 :    
516 :     \subsection{Power in DC circuits}
517 :    
518 :     In direct current (DC) circuits, the power (energy released per unit time) is given by
519 :     \beq
520 :     P = IV
521 :     \eeq
522 :     where $I$ is the constant current and $V$ is the constant voltage. In
523 :     a device where a DC current can flow, reactive components to not have
524 :     an effect and Ohm's law applies:
525 :     \beq
526 :     V = IR
527 :     \eeq
528 :     where $R$ is the electrical resistance. In this case, we can write
529 :     \beq
530 :     P = IV = I^2R = V^2/R.
531 :     \eeq
532 :     There is no analogue of a DC circuit for an electromagnetic wave.
533 :    
534 :     \subsection{AC circuits: `clean' power}
535 :    
536 :     For an alternating current (wave) source, there are several cases to
537 :     consider. We start with the simplest. A crucial point here is that
538 :     Ohm's law is no longer true in AC circuits, because capacitors and
539 :     inductors can borrow power for a short time and then return it, like a
540 :     wave interacting with a dielectric. The voltage and current are now functions
541 :     of time:
542 :     \beq
543 :     I &=& I(t)\nonumber\\
544 :     V &=& V(t).
545 :     \eeq
546 :    
547 :     It is still true that the instantaneous power consumption (the total energy
548 :     absorbed per unit time) is
549 :     \beq
550 :     P = IV = I(t)V(t).
551 :     \eeq
552 :     However, mains power is tyically varying at 50-60 Hz, so this is not
553 :     an true reflection of the long term behaviour, only what happens on
554 :     the scale of tenths of a second.
555 :    
556 :     If we consider a system driven by a single frequency (clean) wave, the short
557 :     term borrowing of current is reflected by a phase shift between the
558 :     voltage, which is the driving force of a systems, and the current,
559 :     which is the response of the system to the driving force. Let us call
560 :     this phase shift $\phi$.
561 :     \beq
562 :     V(t) &=& V_0 \sin (2\pi f t)\nonumber\\
563 :     I(t) &=& I_0 \sin (2\pi f t+\phi)
564 :     \eeq
565 :     where $f$ frequency and $T = 1/f$ is the period of the wave.
566 :    
567 :    
568 :     \bigskip
569 :     \framebox{
570 :     \begin{minipage}[t]{0.8\linewidth}
571 :    
572 :     It helps to think about voltage and current in electrical circuits in terms
573 :     of liquid flow. The voltage is like an external pressure that wants to make the
574 :     current flow through a pipe (wire). When we say that there is a phase delay
575 :     between current and voltage, we are saying that current and voltage are not
576 :     moving exactly in synch'.
577 :    
578 :     Why would current not start flowing at the same time as the driving
579 :     pressure? There must be some inertia in the system for this to happen.
580 :     In a constant current (D.C.) we will not notice this inertia, because
581 :     it is constant. But if we change the voltage at high speed, the
582 :     inertia becomes more and more noticable. You can imagine trying to saw
583 :     a piece of wood while you are standing on a raft, on choppy water. As
584 :     you try to saw a piece of wood, motion the waves underneath the raft
585 :     interferes with your sawing. Sometimes, pushing while you are pulling
586 :     etc. Thus your ability to transfer energy to the wood depends on the
587 :     phase between your sawing and the waves.
588 :    
589 :     \end{minipage}
590 :     }
591 :     \bigskip
592 :    
593 :     We can compute the average power over a number of cycles $nT$ by
594 :     computing
595 :     \beq
596 :     \langle P\rangle_\phi = \frac{1}{nT} \int_0^{nT} \; I(t)\,V(t)\, dt
597 :     \eeq
598 :     We can evaluate this using two trigonometric identities:
599 :     \beq
600 :     \sin(A+B) &=& \sin A \cos B + \cos A \sin B\\
601 :     \sin^2 X &=& \2(1-\cos 2X)
602 :     \eeq
603 :     Using the first of these to rewrite $I(t)$, we have
604 :     \beq
605 :     \langle P\rangle &=& \frac{I_0V_0}{nT}\int_0^{nT} \left[
606 :     \sin^2\left(\frac{2\pi t}{T}\right)\cos\phi +
607 :     \sin\left(\frac{2\pi t}{T}\right)\cos\left(\frac{2\pi t}{T}\right)\sin\phi
608 :     \right] dt
609 :     \eeq
610 :     Rewriting the first term with the help of the second identity allows us to
611 :     integrate the expression. Most terms vanish showing the power that
612 :     is returned over a whole cycle. We are left with:
613 :     \beq
614 :     \langle P\rangle_\phi &=& \2I_0V_0\cos\phi.
615 :     \eeq
616 :     In terms of the normally quoted root-mean-square (RMS) values:
617 :     \beq
618 :     V_{\rm rms} = \sqrt{\frac{1}{nT}\int_0^{nT} (V(t))^2}
619 :     \eeq
620 :     For a mono-chromatic sine wave, one has simply:
621 :     \beq
622 :     V_{\rm rms} &=& V_0/\sqrt{2}\nonumber\\
623 :     I_{\rm rms} &=& I_0/\sqrt{2},
624 :     \eeq
625 :     we have
626 :     \beq
627 :     \langle P\rangle_\phi &=& I_{\rm rms}V_{\rm rms}\cos\phi.
628 :     \eeq
629 :     The RMS values are the values returned by most measuring devices and
630 :     they are the values quoted on power supplies.
631 :     The cosine factor is sometimes called the ``power factor'' in
632 :     electrical engineering literature. It is generalized below. Clearly
633 :     \beq
634 :     \langle P\rangle_{\phi>0} \le \langle P\rangle_{\phi=0}.
635 :     \eeq
636 :     In other words, the actual power consumption is not necessarily
637 :     as bad as the values one would measure with volt and ammeters.
638 :     This is a pity when we pay our bill, because the power companies
639 :     measure current, not work-done. That means we typically pay more than
640 :     we should for electrical power.
641 :    
642 :    
643 :     \subsection{AC circuits, clipped and dirty power}
644 :    
645 :     Not all power is transferred by a clean harmonic signal like the one
646 :     above. Anything that is connected to power with a reactive load
647 :     (capacitors and induction coils) sends power back into the net and
648 :     adds noise to the regular 50-60 Hz. Moreover, an inability to deliver
649 :     enough current can leave to clipping of the wave form, which generates
650 :     Fourier harmonics. Switched mode power supplies in personal computers,
651 :     and flourescent lighting which is highly reactive can add harmonics to
652 :     the power supply. For that reason, the actual phase difference is not
653 :     just a function of your device, but of all the devices close to your
654 :     device. The result can be inefficient power transfer.
655 :    
656 :    
657 :     A direct calculation of the reduction in power transfer is impractical
658 :     in this case, and one simply defined
659 :     \beq
660 :     PF = \cos\phi \equiv \frac{\langle P\rangle}{ I_{\rm rms}V_{\rm rms}}
661 :     \eeq
662 :    
663 :     More expensive equipment is designed with `power factor corrected'
664 :     electronics that attempts to reduce the reactance of the load and lead
665 :     to a simple $\phi=0$ behaviour. The power factor must be measured in
666 :     situ to truly know what it is.
667 :     \begin{itemize}
668 :    
669 :     \item Some authors claim that power factors
670 :     of $\cos\phi = 0.6$ have been observed in some PC hardware.
671 :    
672 :     \item Some authors suggest that a mean value of $\cos\phi = 0.8$ is a reasoable
673 :     guess.
674 :    
675 :     \item Others claim that in data centres one should assume that $\cos\phi=1$ to
676 :     correctly allow for enough headroom to deal with power demand.
677 :     \end{itemize}
678 :    
679 :     Another side effect of mutliple harmonics is that the RMS value is not
680 :     simply $1/\sqrt{2} = 1/1.4$ of the peak value (amplitude). This leads to a new ratio
681 :     called the ``crest factor'', which is simply:
682 :     \beq
683 :     {\rm Crest} = \frac{I_0}{I_{\rm rms}}.
684 :     \eeq
685 :    
686 :    
687 :     \begin{itemize}
688 :    
689 :     \item For a clean sinusoidal wave, this ratio is simply $\sqrt 2 =1.4$.
690 :    
691 :     \item Some authors claim that the crest factor can be as high as 2-3 for cheap
692 :     computing equipment.
693 :    
694 :     \item Some authors claim that a value of 1.4-1.9 is appropriate for power delivered by a UPS
695 :     (uninterruptible power supply).
696 :    
697 :     \item The crest factor is load dependent.
698 :     \end{itemize}
699 :    
700 :    
701 :     \subsection{Some jargon}
702 :    
703 :     Based on the background above, one sees the following terminology in use,
704 :     often in connection with uninterruptible power supplies.
705 :     \begin{itemize}
706 :    
707 :     \item $I_{\rm rms}V_{\rm rms}$ is referred to as ``VA'' or Volt-Amperes, not ``Watts''.
708 :    
709 :     \item Power consumption is referred to as VA $\times$ PF or Volt-Amperes multiplied
710 :     by the power factor and is measured in ``Watts''.
711 :    
712 :     \end{itemize}
713 :    
714 :    
715 :     \section{Earth/Ground}
716 :    
717 :     Current flows when there is a difference in electrical voltage across a closed
718 :     circuit. It flows from regions of high voltage to regions of low voltage,
719 :     i.e. it is differences, not absolutes that matter.
720 :    
721 :     The Earth or ground literally means the electrical potential of the
722 :     ground beneath a building. This has normally a lower potential than
723 :     anything else and so it is used as a safety device to prevent electric
724 :     shocks.
725 :    
726 :     The idea is that, anything metallic can condiuct electricity. In the
727 :     event of a fault, a metallic box or rack could obtain a high
728 :     voltage. If a person touches this, while standing on the ground, there
729 :     will be a path through that person to Earth and the person will
730 :     receive an electric shock.
731 :    
732 :     If, on the other hand, the metal casing is connected to Earth directly
733 :     by a wire, most of the current will flow through the wire to Earth,
734 :     not through the person, because it is a much better conductor -- hence
735 :     the person will be protected. (There is no point is Earthing/grounding
736 :     a device that has no external metallic parts.)
737 :    
738 :     This theory is simple and striaghtforward, but it has a number of
739 :     other consequences.
740 :     \begin{enumerate}
741 :     \item The voltage/potential of Earth is not constant everywhere.
742 :     This means that currents can flow through the Earthing system of a building
743 :     causing electrical noise and other problems.
744 :    
745 :     \item Loops in the Earth system can cause interference. (The sound of ``mains hum'' one
746 :     hears when turning sound equipment up to high volume is associated with these
747 :     currents. In bad cases, this can prevent signals from being sent along cables.)
748 :    
749 :     \item Earth is often connected to copper pipes that go into the ground.
750 :     A faulty Earth connection can make a plumbing pipe live with a high
751 :     voltage, causing a hazard. In one case, known to the author, a
752 :     computer network cable had a voltage of 240V relative to a nearby chair.
753 :     If the user had touched both at the same time, it would have led to a shock.
754 :    
755 :    
756 :     \end{enumerate}
757 :     Buildings and data centres must have a verfied Earth connection. They should also
758 :     have fuses and circuit breakers to prevent large currents from flowing in the event
759 :     of a fault.
760 :    
761 :    
762 :     \chapter{Cooling and Airflow}
763 :    
764 :     Electronic switching technology works by dumping current to ground
765 :     through semi-conducting materials. This is the basic transistor modus
766 :     operandi. This generates large amounts of heat. Essentially all of the
767 :     electrical power consumed by a device ultimately becomes heat.
768 :    
769 :     The aim of cooling is to prevent the temperature of devices becoming too great.
770 :     If the heat increases, the electical resistance of the devices increases and
771 :     even more energy is wasted as heat. Eventually, the electrical properties of the
772 :     materials will no longer be suitable for their original purpose and the
773 :     device will stop working. It could even melt.
774 :    
775 :     \begin{itemize}
776 :     \item Semiconductor chips can melt if they become too hot.
777 :    
778 :     \item Heat increases electrical resistance, which in turn increases heat production
779 :     since heat power conversion goes like $\sim I^2 R$.
780 :    
781 :     \item Heat is a form of energy. Heat is not dangerous to equipment, but temperature is.
782 :     Temperature is related to energy density. The more concentrated heat is, the higher the
783 :     temperature. Thus we want to spread heat out.
784 :    
785 :     \item If we are constantly producing more heat, then some of it has to be taken away
786 :     to maintain the same temperature.
787 :    
788 :     \item Air, water and liquified gases can be used to cool computing equipment, depending
789 :     on the power they consume. Since these fluids are being used to carry
790 :     heat, the rate of flow of heat away from computing equipment is important.
791 :    
792 :     \end{itemize}
793 :    
794 :    
795 :     \section{Heat and temperature}
796 :    
797 :     Heat and temperature are related through a ``specific heat capacity''. All materials
798 :     have a specific heat capacity which describes the approximate effect of heat on
799 :     their temperature.
800 :    
801 :    
802 :     The specific heat capacity (symbol $c_s$, also called specific heat)
803 :     of a substance is defined as heat capacity per unit mass. The SI unit
804 :     for specific heat capacity is the Joule per kilogram Kelvin,
805 :     J·kg-1·K-1 or J/(kg·K), which is the amount of energy required to
806 :     raise the temperature of one kilogram of the substance by one
807 :     Kelvin. Heat capacity can be measured by using calorimetry.
808 :    
809 :     Heat capacities are not really linear, but for small temperature variations we can think of
810 :     heat capacity as being a constant property and we
811 :     we can write down a linear formula for the relationship between temperature
812 :     and heat energy.
813 :     The formula is the same as the one we exploit for cooling:
814 :     \beq
815 :     \Delta Q = m c_s \Delta T
816 :     \eeq
817 :     where $\Delta Q$ is a change of heat energy.
818 :     In other words temperature increase $\Delta T$, in a fixed mass $m$ of
819 :     any substance, is proportional to the amount of heat added $\Delta$,
820 :     assuming that the mass is constant.
821 :    
822 :    
823 :     If we change the temperature by a lot, we might have to re-evaluate
824 :     the heat capacity of the substance. Measuring the heat capacity of
825 :     water produces different results if the starting point is 20 °C rather
826 :     than 60 °C. Therefore the temperature at which the measurement was
827 :     conducted must be specified for the value to be useful.
828 :    
829 :     \subsection{Conduction and Convection}
830 :    
831 :     \begin{itemize}
832 :     \item {\em Conduction} is the direct transfer of heat by contact. For this, we use the
833 :     heat capacity formula above.
834 :    
835 :     \item {\em Convection} is a a transport of gas around a room due to the fact that,
836 :     as a gas is heated its density decreases under constant pressure, so it gets
837 :     lighter and rising. If the hot air rises, cooler air must fall underneath it.
838 :     This results in a circulation of air called convection.
839 :     \end{itemize}
840 :    
841 :     How do we cool using these mechanisms?
842 :    
843 :     If we bring a material into contact with a hotter substance, heat will
844 :     flow into it by {\em conduction}. Then, if we can remove the hotter
845 :     substance e.g. by flow convection, it will carry the heat away with it.
846 :     Some values of $c_s$ for common
847 :     cooling materials are:
848 :    
849 :     \bigskip
850 :     \begin{center}
851 :     \begin{tabular}{l|l|l}
852 :     Substance & Phase & Specific heat capacity\\
853 :     \hline
854 :     Air (dry) & gas & 1005 J/kg/K\\
855 :     Air (100\% humidity) & gas & 1030 J/kg/K\\
856 :     Air (different source) & gas & 1158 J/kg/K\\
857 :     Water & liquid & 4186 J/kg/K\\
858 :     Copper (room temp) & solid & 385 J/kg/K\\
859 :     Gold (room temp) & solid & 129 J/kg/K\\
860 :     Silver (room temp) & solid & 235 J/kg/K\\
861 :     \end{tabular}
862 :     \end{center}
863 :    
864 :     \bigskip
865 :     As we see, water is about four times as efficient at carrying heat per
866 :     degree rise in temperature than is air. It is therefore
867 :     correspondingly better at cooling than air.
868 :    
869 :    
870 :     Convection also helps to keep heat-sources cool, since energy is literally
871 :     carried away my the motion of the surrounding air or fluid.
872 :    
873 :     \bigskip
874 :    
875 :     \bigskip
876 :     \framebox{
877 :     \begin{minipage}[t]{0.8\linewidth}
878 :    
879 :     Note: Do not confuse the temperature of the air coming out of the
880 :     computer with the temperature of the CPU. Think of when you open an
881 :     oven door, after the inital rush of hot air. Metal objects in your
882 :     oven can be hundreds of degrees Celcius, while the air inside is only
883 :     40-50 degrees Celcius. Bear in mind that cool air is flowing through a
884 :     computer all the time with the aid of a fan. What you need to know is
885 :     not the temperature of the air but the temperature of the components
886 :     like the CPU and memory circuits. The plastics of these chips can melt
887 :     if the computer gets too hot.
888 :    
889 :     \end{minipage}}
890 :    
891 :     \section{Melting temperatures}
892 :    
893 :     It is not likely that heat from power dissipation will cause anything
894 :     to melt. The first parts to melt would be the plastics and polymers:
895 :    
896 :     \bigskip
897 :     \begin{center}
898 :     \begin{tabular}{l|l}
899 :     Material & Melting Point\\
900 :     \hline
901 :     Silicon & 1410 C\\
902 :     Copper & 1083 C\\
903 :     Gold & 1063 C\\
904 :     Silver & 879 C\\
905 :     Polymers& 50-100 C\\
906 :     \end{tabular}
907 :     \end{center}
908 :    
909 :     Today's motherboards come with temperature monitoring software and
910 :     hardware which actually shuts the computer off the CPU temperature
911 :     gets too hot. Even these however are not 100\% fail proof.
912 :    
913 :     \bigskip
914 :     \framebox{
915 :     \begin{minipage}[t]{0.8\linewidth}
916 :    
917 :     CPU maximum operating temperatures lie between 60 and 90 degrees Celcius.
918 :    
919 :     \end{minipage}}
920 :     \bigskip
921 :    
922 :     The reason for this is the way that semicondutors work. They rely on the
923 :     ability to switch small voltages and currents on and off to simulate
924 :     the behaviour of logic gates. To do this, it is necessary to have a
925 :     semi-conductor gap, which electrons cannot cross without assistance.
926 :    
927 :     As the temperature increases more and more electrons can bridge the
928 :     gap without assistance and circuits cease to work, because everything is
929 :     essentially always `switched on'. This happens when the size of the
930 :     gap is of the same order as the thermal energy in the material.
931 :     \beq
932 :     eV \sim kT\\
933 :     0.016 \times 10^{-19} \sim 10^{-23} \times 300K
934 :     \eeq
935 :     where $eV$ is the energy gap and $T$ is the absolute temperature, $k$
936 :     is Boltzmann's constant. With gap values of between 0.016-06 electron volts,
937 :     semiconductors are in a fragile state above room temperature.
938 :    
939 :    
940 :     \section{Strategy for heat transfer}
941 :    
942 :     How do we keep things cool?
943 :    
944 :     \subsection{Principles}
945 :     \begin{itemize}
946 :     \item {\em Convection} dominates heat flow in gases and liquids.
947 :     If one prevents convection
948 :     by placing obstacles that inhibit airflow, temperature will rise rapidly.
949 :    
950 :     \item {\em Conduction} - transfer by contact (friction)
951 :     Good conductors of electricity are generally also good conductors of heat,
952 :     and vice versa. Thus we use metals as heat-sinks and radiators to carry away excess heat.
953 :    
954 :     {\em Heat sinks} and
955 :     {\em heat pipes} can be used to lead heat away from a hot-spot using
956 :     a good conductor to spread heat over a wider area. Heat sinks are placed
957 :     on the CPU in computers, for instance.
958 :    
959 :    
960 :     \item {\em Radiation} - electromagnetic energy, or direct heat radiation. Heat will escape
961 :     by photon radiation if it is not prevented from doing so by reflective walls.
962 :    
963 :     Note that electromagnetic radiation only passed through transparent
964 :     substances. However, a substance that is transparent to visible light
965 :     is not necessarily transparent to heat, which has a much longer
966 :     wavelength. This is the essence of the Greenhouse effect. Visible
967 :     light can enter a Greenhouse through the glass walls, this energy is
968 :     absorbed and some of the energy is radiated back as heat (some of it makes
969 :     plants grow). However not all of the long wavelength heat energy passes
970 :     through the glass. Some is absorbed by the air and heats it up. Eventually,
971 :     it will cool off by radiation of very long wavelengths, but this process
972 :     is much slower than the rate at which new energy is coming in, hence the
973 :     energy density increases and temperature goes up.
974 :    
975 :     \end{itemize}
976 :    
977 :     \subsection{Heat extraction}
978 :    
979 :     Cooling fans exploit the same idea as convection, to transport energy away
980 :     by the actual movement of air (or sometimes fluid).
981 :     \begin{figure}[ht]
982 :     \epsfig{file=airflow.eps,width=12cm}
983 :     \caption{Schematic illustration of air flowing through and around a rack device.}
984 :     \end{figure}
985 :     The rate of flow of volume is proportional to the fixed area of the channel
986 :     cross-section and the length per unit time (velocity) of the coolant passing through it.
987 :     \beq
988 :     \frac{dV}{dt} &\propto& A \frac{dx}{dt}\\
989 :     F &\propto& A v
990 :     \eeq
991 :     You should bear in mind that
992 :     \begin{itemize}
993 :     \item It is the temperature of components inside the computer that is the main worry
994 :     in cooling design.
995 :     \item The temperature of the air coming out depends on many factors, including
996 :     the ambient temperature around the box, the rate of air flow through
997 :     the device and around it, the amount of convection in and around the
998 :     device. humidity etc.
999 :    
1000 :     \item Air is a poor carrier of heat, so if air is getting hot, you know that the
1001 :     metalltic components are sizzling!
1002 :     \end{itemize}
1003 :     In very high speed computers that generate large amounts of heat quickly,
1004 :     liquids such as water and nitrogen are use for cooling. The density of a liquid means
1005 :     that it is able to carry much more heat, and hence a smaller flow is needed to carry a
1006 :     larger amount of waste power.
1007 :    
1008 :     \part{Equipment}
1009 :    
1010 :     \chapter{Installing Blade Servers}
1011 :    
1012 :     The blade servers in the lab contain pluggable micro-computers and an inbuilt
1013 :     switch module that connects the array of blades to the outside world.
1014 :    
1015 :     \section{Switch installation}
1016 :    
1017 :     \begin{figure}[ht]
1018 :     \epsfig{file=images/bay2.eps,width=10cm}
1019 :     \caption{The empty I/O bay (bay 2) on the rear of the blade chassis.\label{bay2.eps}}
1020 :     \end{figure}
1021 :     \begin{figure}[ht]
1022 :     \epsfig{file=images/bay2sw.eps,width=10cm}
1023 :     \caption{The switch module is plugged into bay 2.\label{bay2sw.eps}}
1024 :     \end{figure}
1025 :     \begin{figure}[ht]
1026 :     \epsfig{file=images/bay2swin.eps,width=10cm}
1027 :     \caption{Switch module locks into place.\label{bay2swin.eps}}
1028 :     \end{figure}
1029 :     \begin{figure}[ht]
1030 :     \epsfig{file=images/bay2swdone.eps,width=10cm}
1031 :     \caption{The installed switch module.\label{bay2swdone.eps}}
1032 :     \end{figure}
1033 :     \begin{figure}[ht]
1034 :     \epsfig{file=images/blade1.eps,width=10cm}
1035 :     \caption{A blade server, unpacked.\label{blade1.eps}}
1036 :     \end{figure}
1037 :     \begin{figure}[ht]
1038 :     \epsfig{file=images/openblade.eps,width=10cm}
1039 :     \caption{Quick release pressure points on the side allow the cover to be removed.\label{openblade.eps}}
1040 :     \end{figure}
1041 :     \begin{figure}[ht]
1042 :     \epsfig{file=images/insertdisk.eps,width=10cm}
1043 :     \caption{A disk can be plugged in easily.\label{insertdisk.eps}}
1044 :     \end{figure}
1045 :     \begin{figure}[ht]
1046 :     \epsfig{file=images/emptybay.eps,width=10cm}
1047 :     \caption{A filler blade is removed to allow insertion of the server into the blade chassis.\label{emptybay.eps}}
1048 :     \end{figure}
1049 :     \begin{figure}[ht]
1050 :     \epsfig{file=images/insert.eps,width=10cm}
1051 :     \caption{The blade server slide in, with locking clamps extended.\label{insert.eps}}
1052 :     \end{figure}
1053 :     \begin{figure}[ht]
1054 :     \epsfig{file=images/inplace.eps,width=10cm,angle=90}
1055 :     \caption{A single blade server locked in place.\label{inplace.eps}}
1056 :     \end{figure}
1057 :     \begin{figure}[ht]
1058 :     \epsfig{file=images/fullbay.eps,width=10cm}
1059 :     \caption{Six blades installed. Note that the filler blades should be in place in the empty bays, in order to regulate the airflow through the cavity. If the fillers are not inserted, too much air is sucked through the opening, missing the actual blade servers.\label{fullbay.eps}}
1060 :     \end{figure}
1061 :     \begin{figure}[ht]
1062 :     \epsfig{file=images/powerbutton.eps,width=10cm}
1063 :     \caption{Blades are activated by a power button, underneath the cover. A keyboard, screen and CDROM switch also allow selection of the common managment resources.\label{powerbutton.eps}}
1064 :     \end{figure}
1065 :     \begin{figure}[ht]
1066 :     \epsfig{file=images/poweron.eps,width=10cm}
1067 :     \caption{Blades powered up.\label{poweron.eps}}
1068 :     \end{figure}
1069 :     \begin{figure}[ht]
1070 :     \epsfig{file=images/bios.eps,width=10cm}
1071 :     \caption{BIOS boot screen from the powered blade.\label{bios.eps}}
1072 :     \end{figure}
1073 :    
1074 :    
1075 :    
1076 :     \section{Switch configuration}
1077 :    
1078 :     The management module of the blade chassis has a network interface as
1079 :     well as a screen, keyboard, mouse connector. This ethernet connection
1080 :     is on a private VLAN exclusively for connecting to the chassis blade
1081 :     centre.
1082 :    
1083 :     If this ethernet interface is connected to a switch with a DHCP service,
1084 :     within two minutes of powering up the chassis, it will use DHCP to assign a
1085 :     network address. If the two minutes expires, the default address
1086 :     192.168.70.125 is set.
1087 :    
1088 :     We can therefore connect to it using a remote terminal, e.g.
1089 :    
1090 :     \begin{enumerate}
1091 :     \item Start a Linux laptop.
1092 :    
1093 :     \item Connect to the laptop to the management interface using a crossover (null-modem) cable.
1094 :     \item Configure the network interface of the terminal to be part of this
1095 :     private subnet. e.g.
1096 :     \begin{verbatim}
1097 :     ifconfig eth0 192.168.70.2 netmask 255.255.255.0 broadcast 192.168.70.255
1098 :     \end{verbatim}
1099 :     \item With this configuration, one can point a web browser to the addess
1100 :     \begin{verbatim}
1101 :     http://192.168.70.125
1102 :     \end{verbatim}
1103 :     \end{enumerate}
1104 :    
1105 :     We should enable INT1 - INT 6 for connect up the blades
1106 :     internally. Then we should configure EXT1 to allow external
1107 :     connection. For this we must enable trunking on VLAN1, which is the
1108 :     default VLAN for the blades.
1109 :    
1110 :     \begin{figure}[ht]
1111 :     \epsfig{file=images/ibm-1.eps,width=15cm}
1112 :     \caption{The web interface on 192.168.70.125 of the management console. Select I/O modules, Task management, Bay 2 and the Advanced Management option.}
1113 :     \end{figure}
1114 :    
1115 :    
1116 :     \begin{figure}[ht]
1117 :     \epsfig{file=images/ibm-sw1.eps,width=16cm}
1118 :     \caption{Entering the switch module management interface. Select, for instance,
1119 :     the EXT1 interface, i.e. interface number 1 on the switch module we
1120 :     installed in Bay 2. Note the dashboard and configure switches at the
1121 :     top of the screen. Some options are only allowed in configure.}
1122 :     \end{figure}
1123 :    
1124 :     \begin{figure}[ht]
1125 :     \epsfig{file=images/ibm-sw2.eps,width=16cm}
1126 :     \caption{Inside the Advanced Management of the swicth, enable an external port for connecting the blade server chassis to an external switch or router. Enable external port and management of external port.}
1127 :     \end{figure}
1128 :    
1129 :     Once the external interface has been configured, the single external network
1130 :     connection can be used to transfer the internal IP interfaces of the blade
1131 :     servers to the outside world. One does not need to use a separate external
1132 :     ethernet connecter per blade. The purpose of multiple interfaces is to allow
1133 :     multiple VLANs. .
1134 :    
1135 :    
1136 :     \section{Installation of Linux}
1137 :    
1138 :     A number of CDs arrive with the blades. These contain drivers for MS Windows
1139 :     and management software for RAID configuration. We shall not consider RAID
1140 :     here, since our blades each have only a single disk.
1141 :    
1142 :     None of the disks are needed for installation of Linux on the blade servers.
1143 :     Any recent Linux will probably work. We have tested:
1144 :    
1145 :     \begin{enumerate}
1146 :     \item SuSE 10.1
1147 :     \end{enumerate}
1148 :    
1149 :     Eahc blade appears to have two network interfaces which are not easily
1150 :     distinguishable. Although both can be configured with an IP address
1151 :     (even automatically with DHCP), Only one of the two works to connect
1152 :     the blade server to the outside world. You will have to find out which
1153 :     by trial and error.
1154 :    
1155 :     If the switch communication has been enabled,
1156 :     the interfaces are configured in the usual way for the operating system
1157 :     concerned.
1158 :    
1159 :    
1160 :     \part{Planning for High Volume Services}
1161 :    
1162 :    
1163 :     \chapter{Designing an application architecture}
1164 :    
1165 :    
1166 :     The architypical deisgn for network application services
1167 :     is the so-called three tier architectures: webserver, application, database.
1168 :    
1169 :    
1170 :    
1171 :     \section{Failure modes and redunancy}
1172 :    
1173 :     Look up the Folk theorems about redundancy in the Analytical textbook.
1174 :     Redundancy is key issue in handling quality of service. There is a
1175 :     host of reasons why we might not be able to deliver on our promised
1176 :     level of services.
1177 :     \begin{figure}[ht]
1178 :     \epsfig{file=serverrom.eps,width=6cm}
1179 :     \caption{Load balaning is a tricky matter if one is looking for redundancy.
1180 :     A load balancer is a tree -- which is a structure with many intrinsic points
1181 :     of failure and bottlenecks.}
1182 :     \end{figure}
1183 :    
1184 :     When planning redudancy, there are certain thumb rules and theorems
1185 :     concerning system reliability. Fig. \ref{folkth} illustrates the difference
1186 :     between ``correct'' use of redundancy and a flawed strategy.
1187 :    
1188 :     \begin{figure}[ht]
1189 :     \epsfig{file=folkth.eps,width=6cm}
1190 :     \caption{Redundancy folk theorem.\label{folkth}}
1191 :     \end{figure}
1192 :    
1193 :    
1194 :     Here is a minimum dpendency and redundancy strategy. Each of the doubled
1195 :     components can be scaled up to $n$ to increase thoughput.
1196 :    
1197 :     \begin{figure}[ht]
1198 :     \epsfig{file=room.eps,width=6cm}
1199 :     \caption{Minimum redundancy strategy\label{room}}
1200 :     \end{figure}
1201 :    
1202 :     \section{Basic queueing theory for capacity planning}
1203 :    
1204 :     \begin{todo}
1205 :     Read the papers by Bjørnstad and Burgess, and Burgess and Undheim about
1206 :     how well queueing models reflect actual practice.
1207 :     \end{todo}
1208 :    
1209 :     Service provision is usually modelled as a relationship between a
1210 :     client and a server (or service provider). A stream of requests
1211 :     arrives randomly at the input of a system, at a rate of $\lambda$
1212 :     transactions per second, and they are added to a queue, whereupon they
1213 :     are serviced at a rate $\mu$ transactions per second by a processor.
1214 :     \index{Arrivals}\index{Queue}
1215 :    
1216 :     Generalizations of this model include the possibility of multiple
1217 :     (parallel) queues and multiple servers. In each case one considers a
1218 :     single incoming stream of transaction requests; one then studies how to
1219 :     cope with this stream of work.
1220 :    
1221 :     As transaction demand is a random process,
1222 :     queues are classified according to the type of arrival process for
1223 :     requests, the type of completion process and the number of servers. In the
1224 :     simplest form, Kendall notation of the form $A/S/n$ is used to classify
1225 :     different queueing models.
1226 :     \begin{itemize}
1227 :     \item $A$: the arrival process distribution, e.g. Poisson arrival times, deterministic arrivals, or general spectrum arrivals.
1228 :     \item $S$: the service completion distribution for job processing, e.g. Poisson renewals, etc.
1229 :     \item $n$: the number of servers processing the incoming queue.
1230 :     \end{itemize}
1231 :     \index{Distribution!arrivals}
1232 :    
1233 :     \subsection{The Poisson assumption}
1234 :    
1235 :     \index{Distribution!Poisson}
1236 :     \index{Distribution!Memoryless}
1237 :     The distribution of inter-arrival times for both $A$ and $S$ is
1238 :     normally considered to be a Poisson distribution in discrete time. One
1239 :     writes this $M/M/n$ . This assumption is made in order to simplify the
1240 :     analysis. $M$ stands for `memoryless' because the Poisson
1241 :     distribution, taken over non-overlapping time intervals is a Markov
1242 :     process whose behaviour, at any discrete time $t$, is quite independent of
1243 :     what has happened in the past, i.e. it has no memory of the past.
1244 :     The provides a huge simplification of the analysis.
1245 :    
1246 :     Another reason for the Poisson assumption is that, in the limit of
1247 :     large numbers of independent arrivals, one would expect the limiting
1248 :     distribution to have a Poisson form. The argument, on very general
1249 :     grounds is based on the fact that a Poisson distribution is the
1250 :     limiting form of any Bernoulli process in which an event either occurs
1251 :     or does not occur at time $t$. Suppose the probability of obtaining
1252 :     a result is fixed and is equal to $p$ on each independent observation, then
1253 :     the probability of obtaining $q$ positive arrivals in $n$ observations
1254 :     is
1255 :     \beq
1256 :     P(q) = ^nC_q \;p^q (1-p)^{n-q},
1257 :     \eeq
1258 :     where $^nC_r = n!/(n-r)!r!$ are the binomial coefficients. This is a
1259 :     binomial distribution whose mean value is $\overline q = np$. Now,
1260 :     suppose the probability of observing an arrival is scarce
1261 :     i.e. $p\rightarrow 0$, but we consider the limit of long times or many
1262 :     observations $n\rightarrow\infty$, taking the limit in such a way as to
1263 :     make $np\rightarrow \lambda$, where $\lambda$ is a constant. Then, noting the
1264 :     limits,
1265 :     \beq
1266 :     ^nC_r &\le& \frac{n^r}{r!}\nonumber\\
1267 :     ^nC_r &\ge& \frac{n^r}{r^r}\nonumber\\
1268 :     \lim_{\alpha\rightarrow\infty} (1-x)^\alpha &\rightarrow& {\rm e}^{-\alpha} ~~~{\rm where}~ (x < 1).
1269 :     \eeq
1270 :     one observes that
1271 :     \beq
1272 :     P(q=k) \le \frac{n^k}{k!}p^k(1-p)^{n-k} \rightarrow \frac{(np)^k}{k!}(1-p)^{n-k}
1273 :     \rightarrow \frac{\lambda^k}{k!}{\rm e}^{-\lambda},
1274 :     \eeq
1275 :     which is the the Poisson distribution, for which one verifies that
1276 :     $\sum_{k=0}^\infty P(q=k) = 1$.
1277 :    
1278 :     This widely held belief is somewhat controversial, however, as
1279 :     measurements of network traffic have shown evidence of considerable
1280 :     `burstiness', or long-tailed behaviour\cite{paxson2,paxson3,paxson4,leland2}.
1281 :     Other work indicates that these contradictory measurements would in
1282 :     fact settle into a Poisson distribution if only enough measurements
1283 :     were taken\cite{cao2,hopcroft1}. However, it is estimated that
1284 :     something of the order of $10^{10}$ transactions might be needed to
1285 :     see this limiting form emerge.
1286 :    
1287 :     Regardless of this controversy, the Poisson model survives in queueing
1288 :     theory for its overriding simplicity.
1289 :     \index{M/M/s queue}
1290 :    
1291 :     \subsection{$M/M/s$ queues}
1292 :    
1293 :     The basic ideas about queueing can be surmised from the simplest model
1294 :     of a single server, memoryless queue: $M/M/1$. Then, let $n$ be the number
1295 :     of unprocessed requests in the queue at time $t$, and suppose that
1296 :     requests for transactions arrived at a rate of $\lambda$ per second,
1297 :     and can be processed at a rate of $\mu$ per second.
1298 :    
1299 :     We can treat this simple case as a continuum flow approximation, using
1300 :     expectation values.
1301 :    
1302 :     Consider any time $t$: the system makes a transition from a state of
1303 :     queue length $n-1$ to $n$ at a continuous rate $\lambda$. Similarly,
1304 :     when it is in state $n$, it makes transitions to a state of length $n$
1305 :     at a rate $\mu$.
1306 :     The expectation of $\lambda$ arrivals per
1307 :     second, when the queue length is in a state $n-1$ (for any $n$) must therefore
1308 :     lead to the expectation of having $\mu$ completions when the state is
1309 :     $n$, in order to balance the queue, so we write, on balance
1310 :     $\lambda p_{n-1} = \mu p_n$
1311 :     or
1312 :     \beq
1313 :     p_n = \rho p_{n-1},
1314 :     \eeq
1315 :     where $\rho = \lambda/\mu < 1$ is called the traffic intensity\cite{burgessbook2,jain1}.
1316 :     This is a recurrence relation that can be solved for the entire distribution
1317 :     $p_n$, for all $n$. One finds that
1318 :     \beq
1319 :     p_n = (1-\rho)\rho^n,
1320 :     \eeq
1321 :     and hence, the expected length of the queue is
1322 :     \beq
1323 :     \langle n\rangle = \sum_{n=0}^\infty p_n n = \frac{\rho}{1-\rho}.
1324 :     \eeq
1325 :     Clearly as the traffic intensity $\rho$ approaches unity, or $\lambda \rightarrow\mu$,
1326 :     the queue length becomes infinite, as the server loses the ability to cope.
1327 :     \index{Traffic intensity}\index{Intensity!traffic}
1328 :    
1329 :     This situation improves somewhat for $s$ servers ($M/M/s$), where one finds
1330 :     a much more complicated expression. In simplified form one has
1331 :     \beq
1332 :     \langle n \rangle = s\rho + P(n\ge s)\frac{\rho}{1-\rho}
1333 :     \eeq
1334 :     where the probability that the queue length exceeds the number
1335 :     of servers $P(n\ge s)$ is of order $\rho^2$ for small load $\rho$,
1336 :     which naturally leads to smaller queues.
1337 :    
1338 :     It is possible to show that a single queue with $s$ servers is at least
1339 :     as efficient as $s$ separate queues with their own server. This satisfies the
1340 :     intuition that a single queue can be kept moving by any spare capacity
1341 :     in any of its $s$ servers, whereas an empty queue that is separated from the
1342 :     rest will simply be wasted capacity, while the others struggle with the load.
1343 :    
1344 :    
1345 :     \subsection{Flow laws in the continuum approximation}
1346 :    
1347 :     \index{Workflow}\index{Throughput}
1348 :     Dimensional analysis provides us with some simple continuum relationships
1349 :     for the `workflows'.
1350 :     Consider the following definitions:
1351 :     \beq
1352 :     {\rm Arrival~rate~} \lambda &=& \frac{\rm No.~of~ arrivals}{\rm Time} = \frac{A}{T}\\
1353 :     {\rm Throughput~} \mu &=& \frac{\rm No.~of~completions}{\rm Time} = \frac{C}{T}\\
1354 :     {\rm Utilization~} U &=& \frac{\rm Busy~time}{\rm Total~time} = \frac{B}{T}\\
1355 :     {\rm Mean~service~time~} S &=& \frac{\rm Busy~Time}{\rm No.~of~completions} = \frac{B}{C}.
1356 :     \eeq
1357 :     \index{Utilization law}
1358 :     The utilization $U$ tells us the mean level at which resources
1359 :     are being scheduled in the system. The `utilization law' notes simply that:
1360 :     \beq
1361 :     U = \frac{B}{T} = \frac{C}{T}\times\frac{B}{C}
1362 :     \eeq
1363 :     or
1364 :     \beq
1365 :     U = \mu S.
1366 :     \eeq
1367 :     So utilization is proportional to the rate at which jobs are
1368 :     completed and the mean time to complete a job. Thus it can be interpreted as
1369 :     the probability that there is at least one job in the system.
1370 :     \index{Utilization}
1371 :    
1372 :     \begin{example}
1373 :     Suppose a web server receives hits at a mean rate of 1.25 hits per second,
1374 :     and the server takes an average of 2 milliseconds to reply. The law
1375 :     tells us that the utilization of the server is
1376 :     \beq
1377 :     U = 1.25 \times 0.002 = 0.0025 = 0.25\%.
1378 :     \eeq
1379 :     This indicates to us that the system could probably work at four
1380 :     hundred times this rate before saturation occurs, since $400\times
1381 :     0.25 = 100\%$. This conclusion is highly simplistic, but that is the
1382 :     price for having a simple formula!
1383 :     \end{example}
1384 :    
1385 :     \subsection{Little's Law}
1386 :    
1387 :     \index{Little's law}
1388 :     Another dimensional truism is known as Little's law of queue size. It
1389 :     says that the mean number of jobs in a queue $\langle n\rangle$, is
1390 :     equal to the product of the mean arrival rate $\lambda$ (jobs per
1391 :     second) and the mean response time $R$ (seconds) incurred by the
1392 :     queue:
1393 :     \beq
1394 :     \langle n\rangle = \lambda R.
1395 :     \eeq
1396 :     Note that this equation has the generic form $V=IR$, similar to Ohm's
1397 :     law in electricity. This an analogy is a direct consequence of a
1398 :     simple balanced flow model.
1399 :    
1400 :     In the M/M/1 queue, it is useful to characterize the expected response
1401 :     time of the service centre. In other words, what is the likely time a
1402 :     client will have to wait in order to have a task completed? From
1403 :     Little's law, we know that the average number of tasks in a queue is
1404 :     the product of the average response time and the average arrival rate,
1405 :     so
1406 :     \beq
1407 :     R = \frac{Q_n}{\lambda}&=&\frac{\langle n\rangle}{\lambda}\nonumber\\
1408 :     &=& \frac{1}{\mu(1-\rho)}\nonumber\\
1409 :     &=& \frac{1}{(\mu-\lambda)}.
1410 :     \eeq
1411 :     Notice that this is finite as long as $\lambda \ll \mu$, but as
1412 :     $\lambda \rightarrow \mu$, the response time becomes unbounded.
1413 :    
1414 :     Load balancing over queues is a topic for more advanced queueing
1415 :     theory. Weighted fair queueing and algorithms like round-robin etc.,
1416 :     can be used to spread the load of an incoming queue amongst multiple
1417 :     servers, to best exploit their availability. Readers are referred to
1418 :     refs. \cite{burgessbook2,jain1,queues1,queues2} for more discussion on this.
1419 :     \index{Load balancing}
1420 :    
1421 :    
1422 :     \chapter{Capacity Planning}
1423 :    
1424 :     Let's now see how we can use the queueing results to estimate our needs for
1425 :     a system. Most service systems are I/O bound, i.e. the chief bottleneck is
1426 :     input/output. However, in a data centre environment we have another problem
1427 :     that we do not experience on a small scale: power limitations.
1428 :    
1429 :     Before designing a data center we need to work out some basic numbers, the
1430 :     scales and sizes of numbers involved.
1431 :     \begin{itemize}
1432 :     \item How fast can we process jobs? (CPU rate and number of parallel servers).
1433 :    
1434 :     \item How much memory do we need: how many jobs will be in the system (queue length)
1435 :     and what is the average size of a job in memory?
1436 :    
1437 :     \item How many bytes per second of network arrivals and returns do we expect?
1438 :    
1439 :     \item How many bytes per second of disk activity do we expect?
1440 :    
1441 :     \item What is the power cost (including cooling) of running out servers?
1442 :    
1443 :     \end{itemize}
1444 :    
1445 :     \begin{todo}
1446 :     Collect some facts and figures about today's technologies. Don't just choose the
1447 :     latest and greatest, but also some odler slower technologies that are still in use.
1448 :     \begin{itemize}
1449 :     \item CPU speeds in Hz (cycles per second). Find out for RISC and CISC separately,
1450 :     and, in the case of CISC, find out the average number of clock cycles per instruction.
1451 :     Convert both of these into instructions per second.
1452 :     \item Disk transfer rates in MB/s (SCSI/SATA).
1453 :     \item Network speeds.
1454 :     \item How much does a PC cost?
1455 :     \item How much do different kinds of disks cost?
1456 :     \item How much does electrical power cost?
1457 :     \end{itemize}
1458 :     \end{todo}
1459 :    
1460 :     \section{Simple queue estimates}
1461 :    
1462 :     There is a viewpoint that says, in most systems there will be a point of bottleneck
1463 :     somewhere, and so we should model most systems as M/M/1. Let's use the basic
1464 :     M/M/1 formulae to make some calculations
1465 :    
1466 :     \begin{example}
1467 :     Use the formulae for the M/M/1 queue to calculate the amount of RAM,
1468 :     disk rate and CPU speed to handle the average loads:
1469 :     \begin{enumerate}
1470 :     \item 10 downloads per second of image files 20MB each.
1471 :     \item 100 downloads per second of image files 20MB each.
1472 :     \item 20 downloads per second of resized images to a mobile phone, each image is 20MB and
1473 :     takes 100 CPU cycles per byte render and convert in RAM.
1474 :     \end{enumerate}
1475 :     given that the size of the download request is of the order 100 bytes.
1476 :     \end{example}
1477 :    
1478 :     \begin{enumerate}
1479 :    
1480 :     \item If we have 10 downloads per second, each of 20 MB/s, then we need to process
1481 :     \beq
1482 :     10 \times 20 = 200 MB/s.
1483 :     \eeq
1484 :     Ideally, all of the components in the system will be able to handle
1485 :     data at this rate or faster. (Note that when $\lambda = \mu$, the
1486 :     queue length is not zero but infinite -- can you see why?)
1487 :     Let us suppose that the system disk has an average performance of
1488 :     500 MB/s, then we have:
1489 :     \beq
1490 :     \lambda = \frac{200}{20} = 10 j/s\nonumber\\
1491 :     \mu = \frac{500}{20} = 25 j/s.
1492 :     \eeq
1493 :     Note that we cannot use MB/s for $\lambda$, or the formulae will be
1494 :     wrong. In the worst case, each component of the system must be able
1495 :     to handle this data rate.
1496 :    
1497 :     The average queue length:
1498 :     \beq
1499 :     \langle n\rangle = \frac{\rho}{1-\rho} = \frac{\lambda}{\mu-\lambda} = 5/3 \simeq 3
1500 :     \eeq
1501 :     This tells us that there will be able 3 jobs in the system queue waiting to be
1502 :     processed at any given moment. That means the RAM we need to service the queue
1503 :     will be $3\times 100$ bytes, since each job request was 100 bytes long. Clearly
1504 :     RAM is not much of an issue for a lightly loaded server.
1505 :    
1506 :     The mean response time for the service is
1507 :     \beq
1508 :     R = \frac{1}{\mu-\lambda} = \frac{1}{25-10} = \frac{1}{15} sec.
1509 :     \eeq
1510 :    
1511 :     \item With the numbers above the server would fail long before this limit, since
1512 :     at queue size blows up to infinity as $\lambda\rightarrow 25$ and the server starts thrashing, i.e. it spends all its time managing the queue and not completing jobs..
1513 :    
1514 :     \item Now we have an added processing time. Suppose we assume that the CPU has a clock
1515 :     speed of $10^9$ Hz, and an average of 4 cycles per instruction. Then we process
1516 :     at a rate of 100 CPU cycles per byte, for all 20MB.
1517 :     \beq
1518 :     \frac{20 \times 10^6 \times 100}{10^9} = 2s.
1519 :     \eeq
1520 :     Thus we have a processing overhead of 2 seconds per download, which must be
1521 :     added to the normal queue response time.
1522 :     \beq
1523 :     \lambda = \frac{400}{20} = 20 j/s\nonumber\\
1524 :     \mu = \frac{500}{20} = 25 j/s.\nonumber\\
1525 :     \langle n\rangle = \frac{\rho}{1-\rho} = \frac{\lambda}{\mu-\lambda} = 4\nonumber\\
1526 :     R = \frac{1}{\mu-\lambda} + CPU = \frac{1}{25-20} + CPU = \frac{1}{5} + 2 sec.
1527 :     \eeq
1528 :     Notice that the CPU processing now dominates the service time, so we should look
1529 :     at increasing the speed of the CPU before worrying about anything else.
1530 :     \end{enumerate}
1531 :    
1532 :    
1533 :     \section{Peak load handling}
1534 :    
1535 :     There is always a risk in service provision that (at some time) a
1536 :     level of demand will occur that is more than we can serve. Clearly we
1537 :     would like to avoid such a time.
1538 :    
1539 :     One way to handle this is to design a system that can be extended on demand.
1540 :    
1541 :     \section{Power and cooling}
1542 :    
1543 :     It is quite common for inexperienced staff to underestimate the power
1544 :     and cooling requirements for a data centre. Today, with blade chassis
1545 :     computers, it is possible to pack even more computers into a small
1546 :     space than ever before.
1547 :    
1548 :     More computers means more power, and more cooling. Moreover, it is
1549 :     important to be able to deliver peak power without tripping a fuse or
1550 :     circuit-breaker. As we have learned in earlier in this booklet, the
1551 :     current is the killer.
1552 :    
1553 :     Some conservative numbers on a website, rating a blade chassis at 2kW
1554 :     does not mean that we can get away with a 10A circuit. The blades
1555 :     might peak at a significantly higher usage. Moreover, blade servers
1556 :     are designed with redundant power supplies, meaning that everything
1557 :     should be doubled. That could mean that we end up requiring two
1558 :     independent 20A circuits {\em per blade chassis}. A typical rack can
1559 :     house six or more chassix -- and that is almost 30kW (30VA) of power
1560 :     multiplied by two for redundancy.
1561 :    
1562 :     Note that we add to the power requirement for the computing racks the
1563 :     power required to cool them. If you are using air conditioning -- that
1564 :     will add a significant cost to your electricity bill.
1565 :    
1566 :     We are talking about a power supply to rival any industrial production line.
1567 :    
1568 :     \subsection{Connection}
1569 :    
1570 :     Data centres should be wired by experienced electrical engineers.
1571 :     Some designs require three phase power delivery, most today have both
1572 :     options. Not all electricians are experienced in these matters. Try to
1573 :     contact a company that had experience of high current installations.
1574 :    
1575 :     \subsection{Power saving}
1576 :    
1577 :     Because we use more power by running CPUs at high frequency, there is
1578 :     a calculation to do to see if we can save some power
1579 :     by running more computers at a lower frequency.
1580 :     \begin{todo}
1581 :     See the article about power management by Burgess
1582 :     and Sandnes in this compendium. How relevant is this article to power
1583 :     saving in the data centre? Explain your thoughts, critically.
1584 :     \end{todo}
1585 :    
1586 :     \begin{todo}
1587 :     In the article, it is shown that power increases with the square of
1588 :     the CPU frequency. Can you predict, based on this relationship, the
1589 :     shape of the curve of average power consumptions versus number of
1590 :     CPUs, at constant processing rate. Can you measure this curve experimentally?
1591 :     \end{todo}
1592 :    
1593 :     \begin{todo}
1594 :     Study the example calculation in 7.6 of the article System
1595 :     Administration and the Business Process. Use the price estimates for
1596 :     electricity to draw up an estimate for how long it would take to pay for
1597 :     an extra server, given the savings in power and cooling.
1598 :     \end{todo}
1599 :    
1600 :    
1601 :     \subsection{UPS - Uninterruptible Power Supply}
1602 :    
1603 :     \subsection{Building design}
1604 :    
1605 :     With so much heat being wasted in such a small area, we have to think
1606 :     seriously in the future about how buildings are designed. How do we
1607 :     re-use the power? This topic would make an interesting master project.
1608 :    
1609 :    
1610 :     \chapter{Performance Measurement and Benchmarking}
1611 :    
1612 :     Refer to the book by Jain for more details\cite{jain1}.
1613 :    
1614 :     \section{Planning}
1615 :    
1616 :     Steps in planning:
1617 :     \begin{itemize}
1618 :     \item Place measurement instrumentation.
1619 :     \item Collect data.
1620 :     \item Characterize and understand workload patterns.
1621 :     \item Model and predict performance alternatives.
1622 :     \end{itemize}
1623 :    
1624 :    
1625 :     \section{Common mistakes}
1626 :    
1627 :     \begin{itemize}
1628 :    
1629 :     \item Workload only represents average behaviour -- no outlier stress points.
1630 :     \item Not instrumenting enough to find the source of I/O bottlenecks.
1631 :     \item Measurement uncertainties are ignored.
1632 :     \item Ignoring measurement overhead.
1633 :     \item Not repeating or validating measurements many times to eliminate random uncertainties.
1634 :     \item Not ensuring same conditions.
1635 :     \item Not measuring performance under transient behaviour (rapid bursts)
1636 :     \item Collecting data but not analyzing properly.
1637 :     \end{itemize}
1638 :    
1639 :     %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
1640 :    
1641 :     \part{Load Balancing}
1642 :    
1643 :     \chapter{DNS Load Balancing}
1644 :    
1645 :     %\newtheorem{example}{Example}
1646 :     %\newtheorem{question}{Question}
1647 :    
1648 :     \section{Load Balancing}
1649 :     What do you do when your web server is overloaded with heavy requests?
1650 :     One suggestion is to add hardware upgrades to the server, such as a
1651 :     stronger processor and more memory. Another idea is to support the web
1652 :     site with several servers. Using some kind of request scheduling
1653 :     mechanism, it is then possible to share the load among the available
1654 :     servers. This example, though trivial, outlines the essence of load
1655 :     balancing: Sharing an imposed workload between several ordinary and
1656 :     relatively inexpensive servers, as opposed to handling the entire load
1657 :     on a single high-end node. In simplified queueing theory terms, we are
1658 :     moving from $M/M/1$ to $M/M/k$ or $M/M/1^k$ queues. In other words, we
1659 :     substitute the single server setup with more servers or service
1660 :     channels.
1661 :    
1662 :     Sharing load between servers not only has direct economical effects,
1663 :     it often brings about welcome side effects. One such benefit is the
1664 :     level of redundancy implied by running a load balanced service. Say
1665 :     for example that you serve a corporate web site between ten servers.
1666 :     Then you might afford to lose one or more servers without severely
1667 :     impacting the browsing experience for customers. This approach can
1668 :     easily alleviate software or hardware faults in single nodes. It
1669 :     should be noted, however, that a proper redundant system requires
1670 :     redundancy in all links of the chain.
1671 :    
1672 :     %On the issue of manageability, keeping track of software and general
1673 :     %operation of a computer cluster can be considered a drawback compared
1674 :     %to the monolithic approach. However, with the right tools and
1675 :     %configuration, difficulty of management need not turn out to be the
1676 :     %case at all.
1677 :    
1678 :     It is apparent that the difference between lower and higher levels of
1679 :     load balancing is directly related to granularity and scalability,
1680 :     both when it comes to data handling and for manageability. For
1681 :     example, in a multi-CPU system the task scheduler in the operating
1682 :     system organises processes and threads so that they are load-balanced
1683 :     on the available CPU resources. On this scale we deal with units of
1684 :     CPU cycles and microsecond deltas, which are not directly relevant
1685 :     when we talk about server or network load balancing. However, if we
1686 :     zoom out several orders of magnitude and look at network topologies,
1687 :     we can typically operate with units of packets and bytes, and typical
1688 :     deltas of seconds to hours. This is where load balancing becomes more
1689 :     interesting and manageable in system administration. Towards the
1690 :     topmost levels are considerations such as geographic proximity,
1691 :     routing mechanisms and service level agreements. These are interesting
1692 :     because they move away from details and allow us to get a handle on
1693 :     the big picture of large-scale network traffic and do load balancing
1694 :     of that very same traffic. This implies that we deal with trends and
1695 :     analysis of large amounts of data over very long time spans, typically
1696 :     hours and days, to months and even years.
1697 :    
1698 :     \section{DNS-based Load Balancing}
1699 :     The Domain Name System (DNS) is the global name lookup service in the
1700 :     Internet. It is a distributed, hierarchical and redundant database
1701 :     running on thousands of servers worldwide, each responsible for one or
1702 :     more DNS zones. When a client issues a request for a URL, the browser
1703 :     will first try to resolve the hostname in the URL into an IP address,
1704 :     so that it knows where to send the request. This is where it is
1705 :     possible for a DNS server to influence the outcome of a query,
1706 :     effectively directing the client to a desired or lightly loaded site.
1707 :    
1708 :     While DNS in itself was not designed particularly with the
1709 :     requirements of load balancing in mind, it does provide a limited set
1710 :     of options to facilitate simple balancing schemes. However, together
1711 :     with dynamical back-ends, DNS can be a well suited front-end to robust
1712 :     load balancing mechanisms. The strength of using DNS is its almost
1713 :     universal deployment: Practically every node connected to an IP
1714 :     network is capable of DNS resolving. This makes DNS one of the most
1715 :     desirable \emph{interfaces} for global load sharing implementations.
1716 :     Dynamical back-ends are discussed later.
1717 :    
1718 :     To give an insight into how nameservers respond to queries, consider
1719 :     the listing below, showing what a client would receive (per July 2006)
1720 :     when asking for the IP address of the cnn.com host. This particular
1721 :     output is from the `dig' application, and shows three main sections:
1722 :     The question section echoes the request information; the answer
1723 :     section shows the matching records (if any); the authority section
1724 :     lists the authoritative nameservers for the domain.
1725 :    
1726 :     \setlength{\fboxsep}{0pt}
1727 :     \begin{code}
1728 :     \fvset{numbers=left,commandchars=\\\{\}}
1729 :     \begin{Verbatim}
1730 :     ;; QUESTION SECTION:
1731 :     ;cnn.com. IN A
1732 :    
1733 :     ;; ANSWER SECTION:
1734 :     cnn.com. 300 IN A 64.236.29.120 ;This
1735 :     cnn.com. 300 IN A 64.236.16.20 ;is
1736 :     cnn.com. 300 IN A 64.236.16.52 ;an
1737 :     cnn.com. 300 IN A 64.236.16.84 ;RRset
1738 :     cnn.com. 300 IN A 64.236.16.116 ;with
1739 :     cnn.com. 300 IN A 64.236.24.12 ;eight
1740 :     cnn.com. 300 IN A 64.236.24.20 ;web
1741 :     cnn.com. 300 IN A 64.236.24.28 ;servers
1742 :    
1743 :     ;; AUTHORITY SECTION:
1744 :     cnn.com. 600 IN NS twdns-04.ns.aol.com.
1745 :     cnn.com. 600 IN NS twdns-01.ns.aol.com.
1746 :     cnn.com. 600 IN NS twdns-02.ns.aol.com.
1747 :     cnn.com. 600 IN NS twdns-03.ns.aol.com.
1748 :     \end{Verbatim}
1749 :     \end{code}
1750 :    
1751 :     There are a few interesting properties of the DNS response in the
1752 :     listing. First of all, it is clear that the nameservers return
1753 :     multiple A-records for the cnn.com hostname -- this is known as a
1754 :     resource record set (RRset). It is difficult to determine whether
1755 :     there is a complex algorithm behind the result or if it is simply
1756 :     a random permutation of the available servers. Because ordering of
1757 :     RRsets is never guaranteed, it is likely that the DNS servers use
1758 :     random scheduling. In other words, they do not map server preference
1759 :     to the RRset ordering, such as placing the most preferred server on
1760 :     top of the list.
1761 :    
1762 :     Another point to notice is the time-to-live (TTL) values in the second
1763 :     column indicate that the returned records have a very short caching
1764 :     lifetime, 5 and 10 minutes for the A and NS records, respectively. A
1765 :     low TTL ensures that DNS servers are queried often, and are thus
1766 :     able to influence the answer over relatively small time intervals,
1767 :     e.g.~removing dead servers from the RRset. Low TTLs come at the cost
1768 :     of higher frequency of queries, which can add a considerable delay to
1769 :     the total page response time.
1770 :    
1771 :     \section{Configuring BIND}
1772 :     A simple setup of DNS load balancing in the BIND software takes very
1773 :     little effort. The following listing is an example taken from a normal
1774 :     BIND zone file with standard syntax, and it describes the fictional
1775 :     \url{test.lan} zone:
1776 :     \setlength{\fboxsep}{0pt}
1777 :     \begin{code}
1778 :     \fvset{numbers=left,commandchars=\\\{\}}
1779 :     \begin{Verbatim}
1780 :     \$TTL 60
1781 :     test.lan. IN SOA ns.test.lan. hostmaster.test.lan. (
1782 :     1 ; Serial
1783 :     604800 ; Refresh
1784 :     86400 ; Retry
1785 :     2419200 ; Expire
1786 :     604800 ) ; Negative Cache TTL
1787 :     ;
1788 :     test.lan. IN NS ns.test.lan. ; NameServer record.
1789 :     ns IN A 10.0.0.1 ; A-record for nameserver.
1790 :     www IN A 10.0.0.13
1791 :     www IN A 10.0.0.11
1792 :     www IN A 10.0.0.14
1793 :     www IN A 10.0.0.16
1794 :     www IN A 10.0.0.15
1795 :     www IN A 10.0.0.12
1796 :     \end{Verbatim}
1797 :     \end{code}
1798 :     The first line defines the time-to-live value to use for all the
1799 :     records contained within the zonefile. Next, on lines 2 through 7, is
1800 :     the \emph{start of authority} record, which describes behaviour of
1801 :     slave nameservers. The relevant records are the six A-records that
1802 :     make up the RRset for the \url{www.test.lan} hostname. As a result,
1803 :     any lookup for the A-record for \url{www.test.lan} would return the
1804 :     entire set of addresses to the querying client. The default scheduling
1805 :     mechanism in BIND has been known to vary with releases, but is
1806 :     typically set to either random or round-robin with an arbitrary
1807 :     starting order. It can be configured in the \emph{named} configuration
1808 :     options, using the directive ``rr-set ordering''.
1809 :    
1810 :     \section{Dynamical DNS Zones}
1811 :     The current (July 2006) DNS scheme deployed on \url{amazon.com} offers
1812 :     another approach to load sharing. When querying the DNS servers for
1813 :     the A record of \url{www.amazon.com}, only one address is returned.
1814 :     Subsequent queries show that the server returns a single IP address
1815 :     out of a small set. The effects of this approach are twofold. On one
1816 :     side it lets the DNS servers decide which server the client connects
1817 :     to -- i.e. the load sharing is very much more controlled than in the
1818 :     previous CNN example. On the other hand this solution introduces a
1819 :     single point of failure for short periods of time: The client is given
1820 :     only one point of correspondence; should it fail, the client must give
1821 :     up or wait for the TTL to expire. By then, Amazon might have lost
1822 :     their customer.
1823 :    
1824 :     Is there a middle ground here, that is, a compromise between load
1825 :     sharing control and availability? Such a compromise could be
1826 :     implemented by having the DNS servers reply with a \emph{subset} of
1827 :     the full list of servers. It can be argued that this solution provides
1828 :     both the control and availability needed for a high-volume site.
1829 :    
1830 :     When implementing dynamical DNS zones, there is some choice of software.
1831 :     For many years the PowerDNS package has been a viable alternative to
1832 :     BIND. PowerDNS is an authoritative-only DNS server with a very
1833 :     flexible back-end architecture: It supports loading zones from plain
1834 :     BIND-style zone files, a variety of SQL databases, LDAP, etc. Examples
1835 :     of use include setting server preference using a weight factor, or
1836 :     limiting the result to a subset of the matching A-records.
1837 :    
1838 :     On a side note, the latest version of BIND, v9.4, features the DLZ
1839 :     extension. DLZ, dynamically loadable zones, gives BIND much of the
1840 :     same back-end capabilities as PowerDNS when it comes to serving
1841 :     dynamical content.
1842 :    
1843 :     \section{Configuring PowerDNS}
1844 :     Configuring PowerDNS zones is done by populating a database of choice
1845 :     with the zone information, and then specifying the SQL query needed to
1846 :     fetch the data in the configuration file. An example of a query from a
1847 :     populated database is shown below. Note that it contains mostly the
1848 :     same information as the static zone file (though the SOA content is
1849 :     truncated):
1850 :     \setlength{\fboxsep}{0pt}
1851 :     \begin{code}
1852 :     \fvset{numbers=left}
1853 :     \begin{Verbatim}
1854 :     # select id,name,type,content,ttl,pref from records;
1855 :    
1856 :     id | name | type | content | ttl | pref
1857 :     ----+--------------+------+---------------------+------+------
1858 :     1 | test.lan | SOA | ns.test.lan hostmast| 86400|
1859 :     2 | test.lan | NS | ns.test.lan | 86400|
1860 :     9 | ns.test.lan | A | 10.0.0.1 | 86400|
1861 :     3 | www.test.lan | A | 10.0.0.11 | 30| 10
1862 :     4 | www.test.lan | A | 10.0.0.12 | 30| 15
1863 :     5 | www.test.lan | A | 10.0.0.13 | 30| 60
1864 :     6 | www.test.lan | A | 10.0.0.14 | 30| 45
1865 :     7 | www.test.lan | A | 10.0.0.15 | 30| 100
1866 :     8 | www.test.lan | A | 10.0.0.16 | 30| 30
1867 :     \end{Verbatim}
1868 :     \end{code}
1869 :     By appending the ``ORDER BY random() LIMIT 1'' expression to the SQL
1870 :     query, only one random record is returned (the Amazon case).
1871 :     Similarly, ``ORDER BY pref LIMIT 3'' would return the three most
1872 :     preferable servers. If the \emph{pref} value is static, the three
1873 :     least preferable servers would never be used. This can be solved by
1874 :     making the pref value dynamically updated using a simple health-check
1875 :     system. An example of such a system would be monitoring server load in
1876 :     short intervals, and updating the pref value to reflect the current
1877 :     load scenario.
1878 :    
1879 :     The practical uses of dynamical zones are many and vary beyond simple
1880 :     weighting of servers. Other properties that can be taken into
1881 :     consideration include individual server response time, connection
1882 :     count, proximity to client, time zone and various traffic
1883 :     characteristics.
1884 :    
1885 :    
1886 :     \section{Exercises}
1887 :     The exercises below are fairly practical, and will give you a feeling
1888 :     of the possibilities of high-level load balancing. They focus on
1889 :     setup and configuration of DNS and some special HA software.
1890 :    
1891 :     \begin{todo}
1892 :     \emph{This exercise is about setting up a dynamically configured DNS
1893 :     zone using PowerDNS, and testing the setup.}
1894 :    
1895 :     \begin{itemize}
1896 :     \item Skim through the PowerDNS documentation to get an impression of
1897 :     the requirements for installation. You will need PowerDNS itself and a
1898 :     supported back-end of your choice. For example you can choose MySQL or
1899 :     PostgreSQL. All these software suites have ready-to-install packages
1900 :     available for most Linux distributions.
1901 :     \item Create a database for use with PowerDNS, and populate it with
1902 :     the required tables. Alter the default table schema to include a
1903 :     weight or preference column.
1904 :     \item Design a simple DNS zone containing a cluster of servers in an
1905 :     RRset. Use a reasonable number of elements in the set to allow
1906 :     testing; five or more is recommended. Implement the zone in the
1907 :     database tables.
1908 :     \item Set a static preference value for each server.
1909 :     \item In the PowerDNS configuration file, set up the \emph{*-query}
1910 :     strings. You can experiment with the SQL queries and observe their
1911 :     effect. Expressions can include \emph{ORDER BY random()}, \emph{ORDER
1912 :     BY \textless col\textgreater}, \emph{LIMIT \textless n\textgreater}, or otherwise any valid SQL supported by
1913 :     the back-end.
1914 :     \item Start the server and test the configuration by running dig. An
1915 :     example of use is \emph{dig @127.0.0.1 a www.test.lan}.
1916 :     \end{itemize}
1917 :     The following set of tasks is a continuation of the above, but with a
1918 :     higher difficulty.
1919 :     \begin{itemize}
1920 :     \item (Optional) Set up the set of servers in a virtual network, and
1921 :     install a web server on them. The servers need not be identical;
1922 :     resource variation is interesting for testing, e.g.~CPU power, RAM,
1923 :     etc.
1924 :     \item (Optional) Create a script on the DNS server that queries the
1925 :     load (or other property) of the web servers. Propagate the values into
1926 :     the database back-end. Make sure the SQL query strings set up in
1927 :     PowerDNS take the preference value into account.
1928 :     \item Vary the load (or other property) on the web servers either
1929 :     artificially or otherwise, and observe whether the DNS server reacts
1930 :     correctly to the measures you impose on the web servers.
1931 :     \end{itemize}
1932 :     \end{todo}
1933 :    
1934 :     \begin{todo}
1935 :     Assuming that the class is divided into groups with two persons in
1936 :     each group. This somewhat complex exercise is about configuring a
1937 :     fully operating ``global'' network. Depending on the number of groups,
1938 :     one or two groups set up a redundant DNS service (two or more DNS
1939 :     servers), while the other groups set up sites using the Linux Virtual
1940 :     Server and keepalived (or similar) load-balancing implementation.
1941 :     \end{todo}
1942 :    
1943 :    
1944 :    
1945 :    
1946 :     \chapter {Server Load Balancing}
1947 :     As web pages become more user friendly and interactive we see that
1948 :     objects such as pictures, media files, cgi scripts and
1949 :     databases are more frequently used. This development causes increased
1950 :     stress on the servers due to intensified cpu usage and a growing need
1951 :     for bandwidth to serve the content. At the same time users expect low
1952 :     latency and high availability. This dilemma can be solved by
1953 :     implementing load balancing between servers serving content to the
1954 :     clients. Load balancing can provide high availability through
1955 :     redundant server solutions, and reduce latency by dividing load.
1956 :    
1957 :    
1958 :     \section{Overview}
1959 :    
1960 :     In this assignment we will use load balancing to distribute packets
1961 :     among a set of equal web servers serving HTTP content. For packet redirection,
1962 :     a Nortel Application Switch 2208 will be used, and the servers will be hosted on 6 IBM
1963 :     bladeservers. Virtual Lans will be used to separate the external and
1964 :     internal traffic, and a separate VLAN should be used for management of
1965 :     the switches.
1966 :    
1967 :     When the first part of the assignment is finished, the experimental
1968 :     setup, we will look at how the different load balancing algorithms
1969 :     compare to each other.
1970 :    
1971 :     \section{\textbf{Part One:} Experimental Setup}
1972 :    
1973 :     In order to perform load balancing we need to configure a topology
1974 :     that allows it. In figure \ref{lab-overview} it is used three virtual
1975 :     lans to separate network traffic, and make all requests pass through
1976 :     the alteon load balancer:
1977 :    
1978 :     \begin{description}
1979 :    
1980 :     \item[VLAN 1 - Administration VLAN (192.168.1/24):] This VLAN is for
1981 :     administration purposes only. The network equipment used is configured
1982 :     with management interfaces on this VLAN for easy access through the
1983 :     network. The baystack switch is configured with management interface
1984 :     192.168.1.2 and the application switch has the address 192.168.1.1.
1985 :     Both these units can be accessed through ssh or telnet depending on
1986 :     configuration. The default gateway for this vlan is 192.168.1.1, which
1987 :     is the interface configured on the application switch.
1988 :    
1989 :     \item[VLAN 10 - Client VLAN (192.168.10/24):] This VLAN is the client
1990 :     VLAN. This is the VLAN which gives us access to the network from the
1991 :     outside. The machines accessible through internet have two interfaces,
1992 :     one of them is located on VLAN 10 with address 192.168.10.2 (see
1993 :     figure \ref{lab-overview}) and uses 192.168.10.1 as gateway.
1994 :     192.168.10.1 is configured on the application switch.
1995 :    
1996 :     \item[VLAN 100 - Server VLAN (192.168.100/24):] This VLAN is created
1997 :     for the servers, which have ip addresses in the range
1998 :     192.168.100.11-16. They all use 192.168.100.1 as default gateway, this
1999 :     address is configured on the application switch.
2000 :     \end{description}
2001 :    
2002 :     \begin{figure}[h]
2003 :     \centering
2004 :     \psfig{file=lab-overview.eps,width=12cm}
2005 :     \caption{Experimental Setup: This drawing shows how
2006 :     you can setup an environment for doing load balancing in the lab. In
2007 :     this setup we have gigabit speeds from the client to the blades.\label{lab-overview}}
2008 :     \end{figure}
2009 :    
2010 :    
2011 :     \subsection{Configuration - Alteon Application Switch}
2012 :     You should start to configure the alteon application switch. The
2013 :     switch should have a management ip of \textbf{10.0.0.1/24}. It is also
2014 :     possible to connect to it using a regular console cable. Below is some
2015 :     of the important configuration changes you should make:
2016 :    
2017 :     \begin{enumerate}
2018 :     \item Create three vlans; 1,10 and 100, and assign the correct ports.
2019 :     Remember to tag the port you
2020 :     use as the trunk between the baystack and the alteon application
2021 :     switch.
2022 :    
2023 :     \item Create three ip interfaces, one for each vlan, and assign them to
2024 :     their correct vlan.
2025 :    
2026 :     \item Create "real" servers, one for each blade.
2027 :    
2028 :     \item Create a group, and then add all the real servers to this group.
2029 :    
2030 :     \item The ports where the blades are attached need to be set as
2031 :     "server" port, and the port where you connect your client needs to be
2032 :     set as "client" port. If you configure the network as in
2033 :     \ref{lab-overview} you will have one port that is both marked as
2034 :     "client" and "server" port.
2035 :    
2036 :     \item Create a virtual ip address, this is the address the clients are
2037 :     accessing to reach the servers. This address should reside on the 100
2038 :     segment. You also need to enable http traffic for this interface. All
2039 :     requests to this address will be load balanced between the real
2040 :     servers you have defined.
2041 :    
2042 :     \item Last you need to attach your defined virtual ip to the group
2043 :     containing the real servers.
2044 :    
2045 :     \end{enumerate}
2046 :    
2047 :     \noindent \textbf{PS!} Remember to apply and then save your
2048 :     configuration. Backup can also be made to a tftp server.\\\\
2049 :     \medskip
2050 :     \noindent \textbf{PS!} Documentation on how to configure load
2051 :     balancing in more detail can be found here:
2052 :     \url{http://www.nortel.com}, look for documents regarding the 2208
2053 :     application switch.
2054 :    
2055 :     \subsection{Baystack Switch}
2056 :     The baystack switch can be configured either through the network, if
2057 :     it has a management ip, or through the console.
2058 :    
2059 :     \begin{enumerate}
2060 :     \item Begin by creating the same three vlans you created on the
2061 :     application switch. Assign the correct ports to the correct vlans. The
2062 :     vlan trunk going to the application switch need to be member of all
2063 :     three vlans, and it needs to be tagged.
2064 :    
2065 :     \item Set a management ip in the vlan 1 segment.
2066 :     \item Set the port connecting the baystack and the application switch
2067 :     to tagged, and enable all three vlans to it.
2068 :     \item Assign vlans to the other ports according to where you connected
2069 :     the other equipment (blades, client).
2070 :     \end{enumerate}
2071 :    
2072 :     \subsection{IBM blades}
2073 :     The blades should all have the same linux distro installed, as well as
2074 :     apache. How you wish to configure apache is up to yourself, but it
2075 :     should be well documented. The blades are capable of handling a lot of
2076 :     requests per second, so it might be wise to install php as well. This
2077 :     way you can create a cpu intensive php script to use when generating
2078 :     traffic, this can help you eliminate the possibility of your
2079 :     client being the bottleneck. You also need to configure addresses on
2080 :     each of the blades that corresponds to the "real" servers you defined
2081 :     on the application switch. And you should use the ip interface
2082 :     attached to VLAN 100 on the application switch as the default gateway.
2083 :    
2084 :     \subsection{Client}
2085 :     On this machine you need to install or create a program to generate
2086 :     traffic against the VIP address you created on the application switch.
2087 :     You also need to configure the interface connected to the baystack
2088 :     with an ip address in the vlan 10 segment. The default gateway should
2089 :     be set to the ip interface you attached to vlan 10 on the application
2090 :     switch. You also need to add routes to all the other vlans, using the
2091 :     same gateway as your default gateway.
2092 :    
2093 :     \section{\textbf{Part Two:} Testing Performance}
2094 :     In part two of the assignment you can choose between three different
2095 :     testing scenarios:
2096 :    
2097 :     \subsection{Benchmarking Algorithms}
2098 :     To be able to compare the efficiency of different load balancing
2099 :     algorithms, you will perform a series of tests with each of the
2100 :     available algorithms and
2101 :     compare the results. Look at properties such as response time
2102 :     and load distribution.
2103 :    
2104 :     \subsection{Scalability}
2105 :     In these experiments you should test how performance
2106 :     scales when adding additional servers. Run tests with increasing
2107 :     rates, and then plot the performance. Try to see if
2108 :     there is a linear increase in performance when adding blades.
2109 :    
2110 :     \subsection{Experiment vs. Queueing models (HARD)}
2111 :     In these experiments you should look at how the blades perform compared
2112 :     to $M/M/k$ and $M/M/1^k$ queueing models.
2113 :    
2114 :     \section{Important Considerations}
2115 :     When doing measurements on the performance of load balancing it is important that
2116 :     we are aware of the constraints. Some of the constraints that apply to
2117 :     this experiment are listed below, these factors should be considered
2118 :     when analyzing the results:
2119 :    
2120 :     \begin{description}
2121 :     \item[Processing power:] Each of the blades in use have limited
2122 :     processing power. When this limit is exceeded it might be difficult to
2123 :     acquire accurate measurements from the blades.
2124 :    
2125 :     \item[Network Bandwith:] All blades are connected to the network with
2126 :     GigaBit (GB) interfaces, but since all blades are connected through
2127 :     one
2128 :     CAT6 Twisted Pair (TP) cable, they share 1GB of bandwidth.
2129 :    
2130 :     \item[Load Balancer:] The load balancer must process packets, and the
2131 :     amount of processing depends on topology and algorithms used. The load
2132 :     balancer could become a limitation in extreme cases.
2133 :    
2134 :     \item[Apache Webserver:] The apache webserver is configured to spawn a
2135 :     limited number of child processes to handle incoming requests. When this limit
2136 :     is reached, it starts to put requests in a queue, and when the queue is full the
2137 :     server do not accept more incoming requests.
2138 :    
2139 :     \item[Client limitations:] Our traffic generator act as a client
2140 :     generating traffic towards the webservers. The client can only
2141 :     generate a limited amount of connections based on a filedescriptor
2142 :     value (each connection needs a filedescriptor).
2143 :    
2144 :     \end{description}
2145 :    
2146 :     \part{Clusters}
2147 :    
2148 :    
2149 :    
2150 :     \include{cluster-gen-tore}
2151 :    
2152 :    
2153 :     \bibliography{LISAbib}
2154 :    
2155 :     \end{document}