Hyperthermia


3

Hyperthermia

Hyperthermia is an antitumoral therapeutic modality. It consists of selective heating of tumors to temperatures above 42 degrees Celsius, while maintaining healthy tissue nearer to physiological temperatures.

Hyperthermia is currently being used as an adjunct to radiation therapy and chemotherapy of superficial malignancies at a number of medical institutions around the world. Nevertheless, use of hyperthermia is limited, compared to chemo- and radiotherapy, despite reported efficacy in both laboratory and clinical application.

This phenomenon is due primarily due to lack of efficient heating applicators capable of heating large volume (or area) tumors that typically require adjuvant therapy up to therapeutic temperatures. In addition, the lack of reliable temperature feedback control systems which can be implemented noninvasively, limits the options of clinicians during treatment. Devices designed to heat these superficially localized (<2-3 cm depth), and often large area disease sites, must satisfy criteria associated with tissue heterogeneities, conformity to body contours, thermometry, patient safety, and production cost. Physiological and anatomical factors increase the complexity of achieving acceptable performance of microwave applicators.

Early microwave hyperthermic antenna designs, had a tendency to be bulky and awkward to couple to the human body. A variety of more or less adequate printed-circuit applicator designs have been proposed for hyperthermia to improve conformity to the body structures. This includes rectangular, circular, ring, spiral, and other more advanced patch radiator shapes.

During the 1990's a new generation of specialized applicators have been developed for superficial heating. The applicators present the following properties:

  • Lightweight and at least partly flexible for fixation over a tumor.
  • Effective power deposition pattern extending to the periphery of the aperture.
  • Relatively simple and low-cost construction.

One issue often discussed amongst clinicians within this field is the importance of noninvasively establishing temperature profiles during hyperthermic therapy. Several methods, including pulse-echo ultrasound, electrical impedance tomography active microwave imaging, magnetic resonance imaging, and microwave radiometry are under investigation.

The research within this field is in the group of Electrical Enginering concentrated on development of new antenna concepts capable of both producing hypertermia and receiving extremely weak radiated electromagnetic waves containing information on the tissue temperature distribution (microwave radiometry).

Examples of antenna designs and experimental configuration: Experimental setup, Antenna designs


Institutt for fysikk og teknologi
Det matematisk-naturvitenskapelige fakultet, UiT, 9037 Tromsø
Oppdatert av overingeniør Fred Klokkervoll den 23.11.2005 13:03
Ansvarlig redaktør: kontorsjef Trond Brattli


Read this page in: Bokmål | English

set width of main cell in netscape 4

Alle UiTø-sider
Avansert søk

Sider:
Viser 1-5 av 5
Research fields
Adaptiv signalbehandling
Hyperthermia
Integrated optics
Gruppemedlemmer
set width of right cell in netscape 4