Absorption apparatus
A fully automated CO2 removal unit consisting of a full absorption/regeneration cycle with towers 0.15m ID and 4 m tall and equipped with steam generator and cross flow heat exchanger.


A range of IR_analysers for acid gases.


Experimental absorption rate data from a cross-flow membrane contactor and predictions of a simulation program developed in the CO2 capture group. The experimental conditions cover the whole range of operation for a full-scale absorption contactor used in CO2-removal from exhaust gas.


The membrane contactor model is a rigorous diffusion-reaction model, solving for the concentration profiles of the reactants and products of the chemical reaction involved when CO2 is absorbed into an amine-solution.
The upper figure shows the liquid side concentration profile of free CO2 in a single membrane tube. Dissolved CO2 is immediately depleted at the liquid surface due to the rapid chemical reaction with the amine. The lower figure shows the corresponding total CO2 concentration of free+bound CO2 in the form of an amine-carbamate ion diffusing into the bulk of the liquid.